Literature DB >> 15291030

A biomechanical comparison of three surgical approaches in bilateral subaxial cervical facet dislocation.

Sung-Min Kim1, T Jesse Lim, Josemaria Paterno, Jon Park, Daniel H Kim.   

Abstract

OBJECT: In bilateral cervical facet dislocation, biomechanical stabilities between anterior locking screw/plate fixation after anterior cervical discectomy and fusion (ACDFP) and posterior transpedicular screw/rod fixation after anterior cervical discectomy and fusion (ACDFTP) have not been compared using the human cadaver, although ACDFP has been performed frequently. In this study the stability of ACDFP, a posterior wiring procedure after ACDFP (ACDFPW), and ACDFTP for treatment of bilateral cervical facet dislocation were compared.
METHODS: Spines (C3-T1) from 10 human cadavers were tested in the intact state, and then after ACDFP, ACDFPW, and ACDFTP were performed. Intervertebral motion was measured using a video-based motion capture system. The range of motion (ROM) and neutral zone (NZ) were compared for each loading mode to a maximum of 2 Nm. The ROM for spines treated with ACDFP was below that of the intact spine in all loading modes, with statistical significance in flexion and extension, but NZs were decreased in flexion and extension and slightly increased in bending and axial rotation; none of these showed statistical significance. The ACDFPW produced statistically significant additional stability in axial rotation ROM and in flexion NZ than ACDFP. The ACDFTP provided better stability than ACDFP in bending and axial rotation, and better stability than ACDFPW in bending for both ROM and NZ. There was no significant difference in extension with either ROM or NZ for the three fixation methods.
CONCLUSIONS: The spines treated with ACDFTP demonstrated the most effective stabilization, followed by those treated with ACDFPW, and then ACDFP. The spines receiving ACDFP also revealed a higher stability than the intact spine in most loading modes; thus ACDFP can also provide a relatively effective stabilization in bilateral cervical facet dislocation, but with the aid of a brace.

Entities:  

Mesh:

Year:  2004        PMID: 15291030     DOI: 10.3171/spi.2004.1.1.0108

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  17 in total

1.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

2.  Cervical facet joint kinematics during bilateral facet dislocation.

Authors:  Manohar M Panjabi; Andrew K Simpson; Paul C Ivancic; Adam M Pearson; Yasuhiro Tominaga; James J Yue
Journal:  Eur Spine J       Date:  2007-06-14       Impact factor: 3.134

3.  The management of bilateral interfacetal dislocation with anterior fixation in cervical spine : comparison with combined antero-posterior fixation.

Authors:  Ki-Hong Kim; Dae-Chul Cho; Joo-Kyung Sung
Journal:  J Korean Neurosurg Soc       Date:  2007-10-20

Review 4.  Comparison of anterior-only versus combined anterior and posterior fusion for unstable subaxial cervical injuries: a meta-analysis of biomechanical and clinical studies.

Authors:  Dong-Yeong Lee; Young-Jin Park; Myung-Geun Song; Kun-Tae Kim; Dong-Hee Kim
Journal:  Eur Spine J       Date:  2021-02-21       Impact factor: 3.134

5.  New reduction technique for the treatment of unilateral locked facet joints of the lower cervical spine : A retrospective analysis of 12 cases.

Authors:  Xinjia Wang; Guanfeng Yao; Yuchun Chen; Weidong Wang; Jican Zeng
Journal:  Orthopade       Date:  2018-03       Impact factor: 1.087

6.  Posterior approach for cervical fracture-dislocations with traumatic disc herniation.

Authors:  Hiroaki Nakashima; Yasutsugu Yukawa; Keigo Ito; Masaaki Machino; Hany El Zahlawy; Fumihiko Kato
Journal:  Eur Spine J       Date:  2010-10-09       Impact factor: 3.134

7.  Mid- to long-term outcome of instrumented anterior cervical fusion for subaxial injuries.

Authors:  Heiko Koller; Jeremy Reynolds; Juliane Zenner; Rosemarie Forstner; Axel Hempfing; Iris Maislinger; Klaus Kolb; Mark Tauber; Herbert Resch; Michael Mayer; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2009-02-06       Impact factor: 3.134

8.  Impact of 2 different posterior screw fixation techniques on primary stability in a cervical translational injury model: A biomechanical evaluation.

Authors:  Ludwig Oberkircher; Julia Riemenschneider; Martin Bäumlein; Tom Knauf; Christopher Bliemel; Steffen Ruchholtz; Antonio Krüger
Journal:  Medicine (Baltimore)       Date:  2022-02-18       Impact factor: 1.817

9.  Construction and accuracy assessment of patient-specific biocompatible drill template for cervical anterior transpedicular screw (ATPS) insertion: an in vitro study.

Authors:  Maoqing Fu; Lijun Lin; Xiangxue Kong; Weidong Zhao; Lei Tang; Jianyi Li; Jun Ouyang
Journal:  PLoS One       Date:  2013-01-10       Impact factor: 3.240

10.  Traumatic unilateral lumbosacral jumped facet without fracture in a child - presentation of a safe treatment strategy for a rare injury.

Authors:  Oszkar Szentirmai; Joshua Seinfeld; Kathryn Beauchamp; Vikas Patel
Journal:  Patient Saf Surg       Date:  2008-11-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.