Literature DB >> 15288941

Towards single molecule analysis in PDMS microdevices: from the detection of ultra low dye concentrations to single DNA molecule studies.

A Ros1, W Hellmich, T Duong, D Anselmetti.   

Abstract

In this paper, we report on the performance of electrophoretical separation and laser-induced fluorescence (LIF) detection of dyes and fluorescently labeled biomolecules in poly(dimethylsiloxane) (PDMS) microdevices. The dyes fluorescein and fluorescein isothiocyanate (FITC) have been separated effectively in nM concentrations. Fluorescein injections gave linear concentration response in the range from 4 to 100 pM. As ultimate detection sensitivity, 100 fM injected fluorescein was obtained. Further, 100 fM injected fluorescein could be detected. This is to our knowledge the smallest electrokinetically injected dye concentration detected on a microchip. Injection studies of fluorescently labeled avidin revealed a theoretical detection limit of 25 nM for laser-induced fluorescence detection in good agreement with separations in glass chips. Furthermore, the injection of several and even one single DNA molecule using a PDMS cross injector has been demonstrated as well as free solution separation of lambda- and T2-DNA (60 pM each) in periodically structured channels.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15288941     DOI: 10.1016/j.jbiotec.2004.04.020

Source DB:  PubMed          Journal:  J Biotechnol        ISSN: 0168-1656            Impact factor:   3.307


  5 in total

1.  Atomic force microscopy study of DNA conformation in the presence of drugs.

Authors:  Valeria Cassina; Davide Seruggia; Giovanni Luca Beretta; Domenico Salerno; Doriano Brogioli; Stefano Manzini; Franco Zunino; Francesco Mantegazza
Journal:  Eur Biophys J       Date:  2010-09-30       Impact factor: 1.733

2.  Detection of immunoglobulins in a laser induced fluorescence system utilizing polydimethysiloxane microchips with advanced surface and optical properties.

Authors:  Walter Schrott; Marek Nebyla; Michal Přibyl; Dalimil Snita
Journal:  Biomicrofluidics       Date:  2011-02-03       Impact factor: 2.800

3.  Magnetic tweezers measurements of the nanomechanical properties of DNA in the presence of drugs.

Authors:  Domenico Salerno; Doriano Brogioli; Valeria Cassina; Diana Turchi; Giovanni Luca Beretta; Davide Seruggia; Roberto Ziano; Franco Zunino; Francesco Mantegazza
Journal:  Nucleic Acids Res       Date:  2010-07-03       Impact factor: 16.971

4.  Pulsed-field separation of particles in a microfluidic device.

Authors:  J Regtmeier; R Eichhorn; T T Duong; P Reimann; D Anselmetti; A Ros
Journal:  Eur Phys J E Soft Matter       Date:  2007-05-11       Impact factor: 1.624

5.  Torsional sensing of small-molecule binding using magnetic tweezers.

Authors:  Jan Lipfert; Sven Klijnhout; Nynke H Dekker
Journal:  Nucleic Acids Res       Date:  2010-07-12       Impact factor: 16.971

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.