Tissue Doppler gated (TDOG) dynamic three-dimensional ultrasound imaging of the fetal heart.

S Brekke1, E Tegnander, H G Torp, S H Eik-Nes.   

Abstract

Dynamic three-dimensional (3D) ultrasound imaging of the fetal heart is difficult due to the absence of an electrocardiogram (ECG) signal for synchronization between loops. In this study we introduce tissue Doppler gating (TDOG), a technique in which tissue Doppler data are used to calculate a gating signal. We have applied this cardiac gating method to dynamic 3D reconstructions of the heart of eight fetuses aged 20-24 weeks. The gating signal was derived from the amplitude and frequency contents of the tissue Doppler signal. We used this signal as a replacement for ECG in a 3D-volume reconstruction and visualization, utilizing techniques established in ECG-gated 3D echocardiography. The reliability of the TDOG signal for fetal cardiac cycle detection was experimentally investigated. Simultaneous recordings of tissue Doppler of the heart and continuous wave (CW) spectral Doppler of the umbilical artery (UA) were performed using two independent ultrasound systems, and the TDOG signal from one system was compared to the Doppler spectrum data from the other system. Each recording consisted of a two-dimensional (2D) sector scan, transabdominally and slowly tilted by the operator, covering the fetal heart over approximately 40 cardiac cycles. The total angle of the sweep was estimated by recording a separate loop through the center of the heart, in the elevation direction of the sweep.3D reconstruction and visualization were performed with the EchoPAC-3D software (GE Medical Systems). The 3D data were visualized by showing simultaneous cineloops of three 2D slices, as well as by volume projections running in cineloop. Synchronization of B-mode cineloops with the TDOG signal proved to be sufficiently accurate for reconstruction of high-quality dynamic 3D data. We show one example of a B-mode recording with a frame rate of 96 frames/s over 20 seconds. The reconstruction consists of 31 volumes, each with 49 tilted frames. With the fetal heart positioned 5-8 cm from the transducer, the sampling distances were approximately 0.15 mm in the beam direction, 0.33 degrees approximately 0.37 mm azimuth and 0.45 degrees approximately 0.51 mm elevation. From this single dataset we were able to generate a complete set of classical 2D views (such as four-chamber, three-vessel and short-axis views as well as those of the ascending aorta, aortic and ductal arches and inferior and superior venae cavae) with high image quality adequate for clinical use. Copyright 2004 ISUOG

Mesh:

Year:  2004        PMID: 15287059     DOI: 10.1002/uog.1094

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  7 in total

Review 1.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

2.  A novel algorithm for comprehensive fetal echocardiography using 4-dimensional ultrasonography and tomographic imaging.

Authors:  Jimmy Espinoza; Juan Pedro Kusanovic; Luís F Gonçalves; Jyh Kae Nien; Sonia Hassan; Wesley Lee; Roberto Romero
Journal:  J Ultrasound Med       Date:  2006-08       Impact factor: 2.153

3.  Standardized views of the fetal heart using four-dimensional sonographic and tomographic imaging.

Authors:  J Espinoza; R Romero; J P Kusanovic; F Gotsch; W Lee; L F Gonçalves; S S Hassan
Journal:  Ultrasound Obstet Gynecol       Date:  2008-02       Impact factor: 7.299

4.  The role of the sagittal view of the ductal arch in identification of fetuses with conotruncal anomalies using 4-dimensional ultrasonography.

Authors:  Jimmy Espinoza; Roberto Romero; Juan Pedro Kusanovic; Francesca Gotsch; Offer Erez; Wesley Lee; Luís F Gonçalves; Mary Lou Schoen; Sonia S Hassan
Journal:  J Ultrasound Med       Date:  2007-09       Impact factor: 2.153

5.  A study of the adult zebrafish ventricular function by retrospective Doppler-gated ultrahigh-frame-rate echocardiography.

Authors:  Ting-Yu Liu; Po-Yang Lee; Chih-Chung Huang; Lei Sun; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

6.  Applicability, usability, and limitations of murine embryonic imaging with optical coherence tomography and optical projection tomography.

Authors:  Manmohan Singh; Raksha Raghunathan; Victor Piazza; Anjul M Davis-Loiacono; Alex Cable; Tegy J Vedakkan; Trevor Janecek; Michael V Frazier; Achuth Nair; Chen Wu; Irina V Larina; Mary E Dickinson; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2016-05-19       Impact factor: 3.732

7.  Four-dimensional ultrasonography of the fetal heart using a novel Tomographic Ultrasound Imaging display.

Authors:  Luís F Gonçalves; Jimmy Espinoza; Roberto Romero; Juan Pedro Kusanovic; Betsy Swope; Jyh Kae Nien; Offer Erez; Eleazar Soto; Marjorie C Treadwell
Journal:  J Perinat Med       Date:  2006       Impact factor: 1.901

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.