PURPOSE: To assess whether characterization of solid focal liver lesions could be improved by using ultrasonographic (US) contrast-specific modes after sulfur hexafluoride-filled microbubble contrast agent injection, as compared with lesion characterization achieved with preliminary baseline US.
MATERIALS AND METHODS: Four hundred fifty-two solid focal hepatic lesions that were considered indeterminate at baseline gray-scale and color Doppler US were examined after microbubble contrast agent injection performed by using low-acoustic-power contrast-specific modes during the arterial (10-40 seconds after injection), portal venous (50-90 seconds after injection), and late (100-300 seconds after injection) phases. Two readers independently and retrospectively reviewed baseline and contrast material-enhanced US scans and classified each depicted lesion as malignant or benign according to standard diagnostic criteria. Sensitivity, specificity, accuracy, and positive and negative predictive values and areas under the receiver operating characteristic curve (Az) were calculated by considering histologic analysis (317 patients) or contrast-enhanced helical computed tomography followed by serial US 3-6 months apart (135 patients) as the reference standards.
RESULTS: Different contrast enhancement patterns were observed according to lesion characteristics. During the late phase, benign lesions were predominantly hyper- or isoechoic relative to the adjacent liver parenchyma, whereas malignant lesions were predominantly hypoechoic. Review of the contrast-enhanced US scans after baseline image review yielded significantly improved diagnostic performance (P <.05). Overall diagnostic accuracy was 49% before versus 85% after review of the contrast-enhanced scan for reader 1 and 51% before versus 88% after review of the contrast-enhanced scan for reader 2. Diagnostic confidence-that is, the Az-was 0.820 before versus 0.968 after review of the contrast-enhanced scan for reader 1 and 0.831 before versus 0.978 after review of the contrast-enhanced scan for reader 2.
CONCLUSION: The use of contrast-specific modes with a sulfur hexafluoride contrast agent led to improved characterization of solid focal liver lesions. Copyright RSNA, 2004

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15286314     DOI: 10.1148/radiol.2322031401

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  103 in total

1.  Differentiation of focal liver lesions using three-dimensional ultrasonography: retrospective and prospective studies.

Authors:  Wen Luo; Kazushi Numata; Manabu Morimoto; Akito Nozaki; Michio Ueda; Masaaki Kondo; Satoshi Morita; Katsuaki Tanaka
Journal:  World J Gastroenterol       Date:  2010-05-07       Impact factor: 5.742

2.  Computer-aided diagnosis for contrast-enhanced ultrasound in the liver.

Authors:  Katsutoshi Sugimoto; Junji Shiraishi; Fuminori Moriyasu; Kunio Doi
Journal:  World J Radiol       Date:  2010-06-28

3.  Contrast-enhanced ultrasound: The evolving applications.

Authors:  Hui-Xiong Xu
Journal:  World J Radiol       Date:  2009-12-31

4.  Detection of focal liver lesions in cirrhotic liver using contrast-enhanced ultrasound.

Authors:  Grace Lai-Hung Wong; Hui-Xiong Xu; Xiao-Yan Xie
Journal:  World J Radiol       Date:  2009-12-31

5.  Malignant focal liver lesions at contrast-enhanced ultrasonography and magnetic resonance with hepatospecific contrast agent.

Authors:  M D'Onofrio; S Crosara; R De Robertis; S Canestrini; V Cantisani; G Morana; R Pozzi Mucelli
Journal:  Ultrasound       Date:  2013-12-13

6.  Contrast-enhanced ultrasonography (CEUS) vs. MRI of the small bowel in the evaluation of Crohn's disease activity.

Authors:  R Malagò; M D'Onofrio; W Mantovani; G D'Alpaos; G Foti; A Pezzato; G Caliari; D Cusumano; L Benini; R Pozzi Mucelli
Journal:  Radiol Med       Date:  2012-01-21       Impact factor: 3.469

7.  Contrast- and non-contrast-enhanced ultrasonography (US) findings of hepatic metastasis from malignant pheochromocytoma/paraganglioma.

Authors:  Sachiko Nakano; Yoshito Tsushima; Tetsuya Higuchi; Ayako Taketomi-Takahashi; Makoto Amanuma
Journal:  Jpn J Radiol       Date:  2012-01-24       Impact factor: 2.374

8.  Characterization of focal liver lesions: comparative study of contrast-enhanced ultrasound versus spiral computed tomography.

Authors:  V Catala; C Nicolau; R Vilana; M Pages; L Bianchi; M Sanchez; C Bru
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

9.  Prospective study of differential diagnosis of hepatic tumors by pattern-based classification of contrast-enhanced sonography.

Authors:  Kazushi Numata; Tetsuo Isozaki; Manabu Morimoto; Kazuya Sugimori; Reiko Kunisaki; Toshio Morizane; Katsuaki Tanaka
Journal:  World J Gastroenterol       Date:  2006-10-21       Impact factor: 5.742

10.  Contrast-enhanced ultrasonographic findings of serum amyloid A-positive hepatocellular neoplasm: Does hepatocellular adenoma arise in cirrhotic liver?

Authors:  Mariko Kumagawa; Naoki Matsumoto; Yukinobu Watanabe; Midori Hirayama; Takao Miura; Hiroshi Nakagawara; Masahiro Ogawa; Shunichi Matsuoka; Mitsuhiko Moriyama; Tadatoshi Takayama; Masahiko Sugitani
Journal:  World J Hepatol       Date:  2016-09-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.