Literature DB >> 15284981

The initial stability of an exeter femoral stem after impaction bone grafting in combination with segmental defect reconstruction.

Stefan B T Bolder1, B Willem Schreurs, Nico Verdonschot, Robin S M Ling, Tom J J H Slooff.   

Abstract

Bone impaction grafting of the femur is associated with more complications when segmental defects are present. The effect of segmental defect repair on initial stem stability was studied in an in vitro study with fresh-frozen goat femora. A standardized medial segmental defect was reconstructed using a cortical strut or a metal mesh. As controls, we used intact femora and femora with a nonreconstructed defect. In all 4 groups, impacted bone grafting was performed in combination with a cemented Exeter stem. Each group contained 5 femora. Reconstructions were dynamically loaded up to 1,500 N. Migration was measured with Roentgen stereophotogrammetric analysis. All cases with a nonreconstructed segmental defect failed into excessive varus rotation. None of the femora with a reconstructed defect failed. Cortical struts and metal meshes were equally effective in creating a stable stem construction (varus rotation, 2.89 +/- 2.27 and 2.27 +/- 0.57, respectively). Reconstructions with a metal mesh were more reproducible, although the obtained stability was significantly lower (P<.01) when compared with impaction grafting in an intact femur (varus rotation, 0.58 +/- 0.36).

Entities:  

Mesh:

Year:  2004        PMID: 15284981     DOI: 10.1016/j.arth.2004.01.009

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  Stability of fused versus nonfused THA femoral impaction grafts.

Authors:  Anneliese D Heiner; John J Callaghan; Thomas D Brown
Journal:  J Orthop Res       Date:  2007-03       Impact factor: 3.494

2.  Initial stability of circumferential meshes with impacted bone allografts for massive femoral defects.

Authors:  Agustín José Guala; Martin Buttaro; Francisco Piccaluga
Journal:  Int Orthop       Date:  2007-04-20       Impact factor: 3.075

3.  Factors influencing the stability of stems fixed with impaction graft in vitro.

Authors:  Hirotsugu Ohashi; Masanori Matsuura; Tsuneyuki Ebara; Yusaku Okamoto; Hironori Kou
Journal:  Clin Orthop Relat Res       Date:  2009-01-29       Impact factor: 4.176

4.  Complete bone remodeling after calcar reconstruction with metal wire mesh and impaction bone grafting: a case report.

Authors:  Toshiki Iwase; Atsushi Kouyama; Naoya Matsushita
Journal:  Nagoya J Med Sci       Date:  2013-08       Impact factor: 1.131

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.