Literature DB >> 15281104

Impact of engineering flow conditions on plasmid DNA yield and purity in chemical cell lysis operations.

F J Meacle1, R Lander, P Ayazi Shamlou, N J Titchener-Hooker.   

Abstract

Chemical lysis of bacterial cells using an alkaline solution containing a detergent may provide an efficient scalable means for selectively removing covalently closed circular plasmid DNA from high-molecular-weight contaminating cellular components including chromosomal DNA. In this article we assess the chemical lysis of E. coli cells by SDS in a NaOH solution and determine the impact of pH environment and shear on the supercoiled plasmid and chromosomal DNA obtained. Experiments using a range of plasmids from 6 kb to 113 kb determined that in an unfavorable alkaline environment, where the NaOH concentration during lysis is greater than 0.15 +/- 0.03 M (pH 12.9 +/- 0.2), irreversible denaturation of the supercoiled plasmid DNA occurs. The extent of denaturation is shown to increase with time of exposure and NaOH concentration. Experiments using stirred vessels show that, depending on NaOH concentration, moderate to high mixing rates are necessary to maximize plasmid yield. While NaOH concentration does not significantly affect chromosomal DNA contamination, a high NaOH concentration is necessary to ensure complete conversion of chromosomal DNA to single-stranded form. In a mechanically agitated lysis reactor the correct mixing strategy must balance the need for sufficient mixing to eliminate potential regions of high NaOH concentrations and the need to avoid excessive breakage of the shear sensitive chromosomal DNA. The effect of shear on chromosomal DNA is examined over a wide range of shear rates (10(1)-10(5) s(-1)) demonstrating that, while increasing shear leads to fragmentation of chromosomal DNA to smaller sizes, it does not lead to significantly increased chromosomal DNA contamination except at very high shear rates (about 10(4)-10(5) s(-1)). The consequences of these effects on the choice of lysis reactor and scale-up are discussed.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15281104     DOI: 10.1002/bit.20114

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  6 in total

1.  On the stability of plasmid DNA vectors during cell culture and purification.

Authors:  S S Freitas; A R Azzoni; J A L Santos; G A Monteiro; D M F Prazeres
Journal:  Mol Biotechnol       Date:  2007-06       Impact factor: 2.695

2.  Protein Extraction by Means of Electroporation from E. coli with Preserved Viability.

Authors:  Sasa Haberl Meglic; Tilen Marolt; Damijan Miklavcic
Journal:  J Membr Biol       Date:  2015-07-23       Impact factor: 1.843

3.  Cell lysis via acoustically oscillating sharp edges.

Authors:  Zeyu Wang; Po-Hsun Huang; Chuyi Chen; Hunter Bachman; Shuaiguo Zhao; Shujie Yang; Tony J Huang
Journal:  Lab Chip       Date:  2019-11-13       Impact factor: 6.799

Review 4.  Bioprocess engineering issues that would be faced in producing a DNA vaccine at up to 100 m3 fermentation scale for an influenza pandemic.

Authors:  Mike Hoare; M Susana Levy; Daniel G Bracewell; Steven D Doig; Simyee Kong; Nigel Titchener-Hooker; John M Ward; Peter Dunnill
Journal:  Biotechnol Prog       Date:  2005 Nov-Dec

5.  Cell Lysis Based on an Oscillating Microbubble Array.

Authors:  Xiufang Liu; Jinyuan Li; Liangyu Zhang; Xiaowei Huang; Umar Farooq; Na Pang; Wei Zhou; Lin Qi; Lisheng Xu; Lili Niu; Long Meng
Journal:  Micromachines (Basel)       Date:  2020-03-10       Impact factor: 2.891

6.  A new device-mediated miniprep method.

Authors:  Baryshev Mikhail; Merkulov Dmitrijs; Mironov Ivan
Journal:  AMB Express       Date:  2022-02-22       Impact factor: 3.298

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.