Literature DB >> 15277929

Factors affecting the spread and duration of epidural anesthesia with ropivacaine.

Hideyuki Higuchi1, Yushi Adachi, Tomiei Kazama.   

Abstract

BACKGROUND: Epidural anesthesia has an unpredictable extent and duration. Differences in the surface area of the lumbosacral dura, epidural fat volume, and epidural venous plexus velocity might explain the variability in the extent and duration of epidural anesthesia with ropivacaine.
METHODS: Twenty-six healthy patients, aged 18-45 y, undergoing peripheral orthopedic surgery were enrolled. Dural surface area and posterior epidural fat volume were calculated from low thoracic, lumbar, and sacral axial magnetic resonance images obtained at 8-mm increments. Epidural venous plexus velocity at the L3-L4 disk level was derived from phase-contrast magnetic resonance images. The patients received 100 mg ropivacaine (1.0%) epidurally. The spread and duration of sensory anesthesia was assessed by pinprick, and that of motor block was assessed using a modified Bromage scale. Statistical correlation coefficients (rho) between magnetic resonance imaging and epidural anesthesia measurements were assessed by Spearman rank correlation. Stepwise multiple linear regression models were used to select important predictors of measures of epidural anesthesia.
RESULTS: Dural surface area correlated with peak sensory block level (rho= -0.73, P = 0.0003) and onset time of caudal and cephalad block (rho = 0.62, P = 0.002; rho = -0.63, P = 0.002). Fat volume correlated with the regression to L5-S3 (rho = -0.44.44 to -0.54, P = 0.029 to 0.007). Epidural venous plexus velocity was significantly correlated with the regression to L3 (rho = -0.42, P = 0.038) and L4 (rho = -0.48, P = 0.017). Multiple regression analysis revealed that dural surface area was a significant predictive variable for the peak sensory block level (R = 0.61, P < 0.0001).
CONCLUSIONS: These findings indicate that dural surface area influences the spread of epidural anesthesia with ropivacaine and posterior fat volume influences the duration of epidural anesthesia in healthy patients within a narrow age range. Epidural venous plexus velocity might also influence the duration of epidural anesthesia with ropivacaine.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15277929     DOI: 10.1097/00000542-200408000-00027

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  14 in total

1.  Epidural anesthesia for the patient with type IV spinal muscular atrophy -A case report-.

Authors:  Seon Jin Kim; Eun Ju Kim; Byung Woo Min; Jong Seouk Ban; Sang Gon Lee; Ji Hyang Lee
Journal:  Korean J Anesthesiol       Date:  2010-12-31

2.  Interaction Between Ropivacaine and a Self-Assembling Peptide: A Nanoformulation for Long-Acting Analgesia.

Authors:  Fei Peng; Jing Liu; Yujun Zhang; Guoyan Zhao; Deying Gong; Liu He; Wensheng Zhang; Feng Qiu
Journal:  Int J Nanomedicine       Date:  2022-07-29

Review 3.  Update on applied epidural anatomy.

Authors:  D Macpherson; F Quondamatteo; M Broom
Journal:  BJA Educ       Date:  2022-02-23

4.  Evaluation of segmental epidural blockade following standard test dose versus test dose with addition of saline in abdominal surgeries.

Authors:  Nandhini Joseph; Lakshmi Kumar; P Shyamsundar; Sindhu Balakrishnan; Rajesh Kesavan; Sunil Rajan
Journal:  Indian J Anaesth       Date:  2020-09-01

5.  The Correlation between Caudal Epidurogram and Low Back Pain.

Authors:  Dae Hyun Jo; Sul Jang
Journal:  Korean J Pain       Date:  2012-01-02

6.  Contribution of Low-Dose Computerized Tomography With Digital Multiplanar Reconstructions in Thoracic Epidurography and Correlation With Sensory Block in Postoperative Analgesia.

Authors:  Cyrus Motamed; Karin Chedevergne; Frederic Deschamps; Lambros Tselikas; Christian Jayr
Journal:  Anesth Pain Med       Date:  2016-05-30

7.  Ropivacaine versus levobupivacaine in peripheral nerve block: A PRISMA-compliant meta-analysis of randomized controlled trials.

Authors:  Ang Li; Zhijian Wei; Yang Liu; Jiaxiao Shi; Han Ding; Haoshuai Tang; Pengyuan Zheng; Yanzheng Gao; Shiqing Feng
Journal:  Medicine (Baltimore)       Date:  2017-04       Impact factor: 1.889

8.  Postoperative pain and patient-controlled epidural analgesia-related adverse effects in young and elderly patients: a retrospective analysis of 2,435 patients.

Authors:  Jae Chul Koh; Young Song; So Yeon Kim; Sooyeun Park; Seo Hee Ko; Dong Woo Han
Journal:  J Pain Res       Date:  2017-04-12       Impact factor: 3.133

9.  Spreading pattern of contrast medium in the high thoracic epidural space in rabbits: the effect of neck flexion and extension.

Authors:  Mi-Hyun Kim; Young Jin Lim; Deok-Man Hong; Yun-Seok Jeon; Hee Pyoung Park; Young-Tae Jeon; Soon Young Shin; Sun Sook Han
Journal:  Korean J Anesthesiol       Date:  2010-08-20

10.  Needle Tip Position and Bevel Direction Have No Effect in the Fluoroscopic Epidural Spreading Pattern in Caudal Epidural Injections: A Randomized Trial.

Authors:  Won Kyoung Kwon; Ah Na Kim; Pil Moo Lee; Cheol Hwan Park; Jae Hun Kim
Journal:  Pain Res Manag       Date:  2016-04-24       Impact factor: 3.037

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.