Literature DB >> 15276524

Three-dimensional echocardiography for planning of mitral valve surgery: current applicability?

Alexander M Fabricius1, Thomas Walther, Volkmar Falk, Friedrich W Mohr.   

Abstract

BACKGROUND: Two-dimensional transesophageal echocardiographic (2D TEE) assessment of the mitral valve requires mental integration of a limited number of 2D imaging planes. Structural display in three dimensions from any perspective may be of advantage to the surgeon for better judgment and planning.
METHODS: Feasibility, accuracy, and limitations of preoperative three-dimensional transesophageal echocardiography (3D TEE) was assessed in 51 patients with mitral valve disease. The width of the anterior mitral valve was measured with either method and compared with the operative finding. Three-dimensional dynamic sequences of the reconstructed mitral valve were shown preoperatively to the surgeon and later compared with the intraoperative finding.
RESULTS: The quality of the 3D reconstruction was graded as good in 25 patients (49.0%), fair in 16 patients (31.4%), and poor in 10 patients (19.6%) where atrial fibrillation did not allow ECG gating. Thirty-nine patients had successful mitral valve repair and twelve patients required valve replacement. Based on intraoperative findings, sensitivity for the diagnosis of mitral valve prolapse using 2D TEE and 3D TEE was 97.7% and 92.9% (p = ns) respectively and specificity was 100% by both methods. Sensitivity for the diagnosis of rupture of chordae tendineae using 2D TEE and 3D TEE was 92.3% and 30.8% respectively (p < 0.05) and specificity was 100% by both methods.
CONCLUSIONS: Dynamic 3D echocardiography is feasible and can provide good insight into valvular motion and allows adequate preoperative planning when reconstruction is being considered. However dynamic 3D reconstruction is currently limited by the quality of the original 2D echo cross sectional images which can be adversely affected by minimal patient movements, breathing, or cardiac arrhythmia, thus limiting accuracy of the 3D TEE significantly compared with 2D TEE.

Entities:  

Mesh:

Year:  2004        PMID: 15276524     DOI: 10.1016/j.athoracsur.2003.10.031

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  12 in total

1.  Mitral valve analysis using a novel 3D holographic display: a feasibility study of 3D ultrasound data converted to a holographic screen.

Authors:  Jan Otto Beitnes; Lars Gunnar Klæboe; Jørn Skaarud Karlsen; Stig Urheim
Journal:  Int J Cardiovasc Imaging       Date:  2014-11-13       Impact factor: 2.357

2.  [Three-dimensional echocardiography in cardiac surgery. Current status and perspectives].

Authors:  M R Hoda; T Schwarz; I Wolf; S Mottl-Link; H P Meinzer; M Karck; R De Simone
Journal:  Chirurg       Date:  2007-05       Impact factor: 0.955

3.  Mitral Annulus Segmentation from Three-Dimensional Ultrasound.

Authors:  Robert J Schneider; Douglas P Perrin; Nikolay V Vasilyev; Gerald R Marx; Pedro J Del Nido; Robert D Howe
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2009

4.  Mitral annulus segmentation from four-dimensional ultrasound using a valve state predictor and constrained optical flow.

Authors:  Robert J Schneider; Douglas P Perrin; Nikolay V Vasilyev; Gerald R Marx; Pedro J del Nido; Robert D Howe
Journal:  Med Image Anal       Date:  2011-12-04       Impact factor: 8.545

5.  Mitral annulus segmentation from 3D ultrasound using graph cuts.

Authors:  Robert J Schneider; Douglas P Perrin; Nikolay V Vasilyev; Gerald R Marx; Pedro J del Nido; Robert D Howe
Journal:  IEEE Trans Med Imaging       Date:  2010-06-17       Impact factor: 10.048

6.  Normal mitral and aortic valve areas assessed by three- and two-dimensional echocardiography in 168 children and young adults.

Authors:  T Poutanen; T Tikanoja; H Sairanen; E Jokinen
Journal:  Pediatr Cardiol       Date:  2006 Mar-Apr       Impact factor: 1.655

Review 7.  Three-dimensional echocardiography. New possibilities in mitral valve assessment.

Authors:  Jorge Solis; Marta Sitges; Robert A Levine; Judy Hung
Journal:  Rev Esp Cardiol       Date:  2009-02       Impact factor: 4.753

8.  Three-dimensional echocardiography in valve disease.

Authors:  Chiara Colombo; Gloria Tamborini; Mauro Pepi; Marina Alimento; Cesare Fiorentini
Journal:  Heart Int       Date:  2007-06-15

9.  Efficacy of chordal cutting in alleviating ischemic mitral regurgitation: insights from 3-dimensional echocardiography.

Authors:  Chittoor B Sai-Sudhakar; Rashmi Vandse; Todd A Armen; Katherine M Bickle; Nadia S Nathan
Journal:  J Cardiothorac Surg       Date:  2007-09-25       Impact factor: 1.637

10.  Effect of leaflet-to-chordae contact interaction on computational mitral valve evaluation.

Authors:  Yonghoon Rim; David D McPherson; Hyunggun Kim
Journal:  Biomed Eng Online       Date:  2014-03-20       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.