Literature DB >> 15271734

Increased cerebral tissue oxygen tension after extensive hemodilution with a hemoglobin-based oxygen carrier.

Gregory M T Hare1, Kathryn M Hum, Steve Y Kim, Aiala Barr, Andrew J Baker, C David Mazer.   

Abstract

Transfusion of anemic patients with hemoglobin-based oxygen carriers (HBOCs) may improve cerebral oxygen delivery. Conversely, cerebral vasoconstriction, associated with HBOC transfusion, could limit optimal cerebral tissue oxygenation. We hypothesized that hemodilution with a HBOC would maintain cerebral tissue oxygenation, despite the occurrence of cerebral vasoconstriction. Isoflurane-anesthetized rats (100% oxygen) underwent direct measurement of mean arterial blood pressure (MAP), caudate tissue oxygen tension (P(Br)o(2)), and regional cortical cerebral blood flow (rCBF) before and after 50% of the estimated blood volume (30 mL/kg) was exchanged with either an HBOC (hemoglobin raffimer; Hemolink) or pentastarch (n = 6). Hemodilution with hemoglobin raffimer caused a transient increase in P(Br)o(2) from 24.9 +/- 13.3 mm Hg to 32.2 +/- 19.1 mm Hg (P < 0.05), a sustained increase in MAP, and no change in rCBF. Arterial blood oxygen content was maintained despite an increase in methemoglobin and reduced oxygen saturation. Hemodilution with pentastarch caused a transient increase in MAP, no change in P(Br)o(2), and a sustained increase in rCBF (P < 0.05), whereas the hemoglobin concentration and oxygen content were significantly reduced. Hemodilution with hemoglobin raffimer augmented P(Br)o(2) and prevented the increase in rCBF observed after similar hemodilution with pentastarch. These data suggest that transfusion with hemoglobin raffimer may help to maintain cerebral oxygenation during severe anemia.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15271734     DOI: 10.1213/01.ANE.0000136769.65960.D1

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

Review 1.  Direct cerebral oxygenation monitoring--a systematic review of recent publications.

Authors:  Erhard W Lang; Jamin M Mulvey; Yugan Mudaliar; Nicholas W C Dorsch
Journal:  Neurosurg Rev       Date:  2007-01-13       Impact factor: 3.042

2.  Inhaled nitric oxide enables artificial blood transfusion without hypertension.

Authors:  Binglan Yu; Michael J Raher; Gian Paolo Volpato; Kenneth D Bloch; Fumito Ichinose; Warren M Zapol
Journal:  Circulation       Date:  2008-04-07       Impact factor: 29.690

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.