Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers.

François Lellouche1, Solenne Taillé, Salvatore M Maggiore, Siham Qader, Erwan L'her, Nicolas Deye, Laurent Brochard.   

Abstract

Although heated humidifiers are considered the most efficient humidification devices for mechanical ventilation, endotracheal tube occlusion caused by dry secretions has been reported with heated-wire humidifiers. We tested the hypothesis that inlet chamber temperature, influenced by ambient air and ventilator output temperatures, may affect humidifier performance, as assessed by hygrometry. Hygrometry was measured with three different humidifiers under several conditions, varying ambient air temperatures (high, 28-30 degrees C; and normal, 22-24 degrees C), ventilators with different gas temperatures, and two VE levels. Clinical measurements were performed to confirm bench measurements. Humidifier performance was strongly correlated with inlet chamber temperature in both the bench (p < 0.0001, r2 = 0.93) and the clinical study. With unfavorable conditions, absolute humidity of inspired gas was much lower than recommended (approximately 20 mg H2O/L). Performance was improved by specific settings or new compensatory algorithms. Hygrometry could be evaluated from condensation on the wall chamber only when ambient air temperature was normal but not with high air temperature. An increase in inlet chamber temperature induced by high ambient temperature markedly reduces the performance of heated-wire humidifiers, leading to a risk of endotracheal tube occlusion. Such systems should be avoided in these conditions unless automatic compensation algorithms are used.

Entities:  

Mesh:

Year:  2004        PMID: 15271695     DOI: 10.1164/rccm.200309-1245OC

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  20 in total

1.  Bench test evaluation of volume delivered by modern ICU ventilators during volume-controlled ventilation.

Authors:  Aissam Lyazidi; Arnaud W Thille; Guillaume Carteaux; Fabrice Galia; Laurent Brochard; Jean-Christophe M Richard
Journal:  Intensive Care Med       Date:  2010-09-23       Impact factor: 17.440

2.  Airway humidification with a heat and moisture exchanger in mechanically ventilated neonates : a preliminary evaluation.

Authors:  Mikaïla Fassassi; Fabrice Michel; Laurent Thomachot; Claire Nicaise; Renaud Vialet; Yves Jammes; Pierre Lagier; Claude Martin
Journal:  Intensive Care Med       Date:  2006-12-13       Impact factor: 17.440

3.  Under-humidification and over-humidification during moderate induced hypothermia with usual devices.

Authors:  François Lellouche; Siham Qader; Solenne Taille; Aissam Lyazidi; Laurent Brochard
Journal:  Intensive Care Med       Date:  2006-05-23       Impact factor: 17.440

4.  Humidification during oxygen therapy and non-invasive ventilation: do we need some and how much?

Authors:  Jean-Damien Ricard; Alexandre Boyer
Journal:  Intensive Care Med       Date:  2009-03-18       Impact factor: 17.440

5.  Intrapulmonary percussive ventilation superimposed on conventional ventilation: bench study of humidity and ventilator behaviour.

Authors:  Jean Dellamonica; Bruno Louis; Aissam Lyazidi; Frédéric Vargas; Laurent Brochard
Journal:  Intensive Care Med       Date:  2008-07-01       Impact factor: 17.440

6.  Frugal innovation for critical care.

Authors:  Armand Mekontso Dessap
Journal:  Intensive Care Med       Date:  2018-10-04       Impact factor: 17.440

7.  Precautions with heated humidifier systems in particular environments.

Authors:  Pierre-Eric Danin; Jean Dellamonica; Gilles Bernardin
Journal:  Intensive Care Med       Date:  2013-05-18       Impact factor: 17.440

8.  Comparison of the effects of two humidifier systems on endotracheal tube resistance.

Authors:  Indalecio Morán; Belén Cabello; Elizabeth Manero; Jordi Mancebo
Journal:  Intensive Care Med       Date:  2011-09-27       Impact factor: 17.440

9.  Water content of delivered gases during non-invasive ventilation in healthy subjects.

Authors:  François Lellouche; Salvatore Maurizio Maggiore; Aissam Lyazidi; Nicolas Deye; Solenne Taillé; Laurent Brochard
Journal:  Intensive Care Med       Date:  2009-03-18       Impact factor: 17.440

10.  Heat and moisture exchangers and heated humidifiers in acute lung injury/acute respiratory distress syndrome patients. Effects on respiratory mechanics and gas exchange.

Authors:  Indalecio Morán; Judith Bellapart; Alessandra Vari; Jordi Mancebo
Journal:  Intensive Care Med       Date:  2006-02-24       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.