Literature DB >> 15270586

Fiducial markers implanted during prostate brachytherapy for guiding conformal external beam radiation therapy.

James S Welsh1, Christine Berta, Scott Borzillary, Celis Sam, Derek Shickell, Lisa Nobile, Marsha Greenberg, Stephanie Weiss, Nicholas Detorie.   

Abstract

Prostate movement imposes limits on safe dose-escalation with external beam radiation therapy. If the precise daily location of the prostate is known, dose escalation becomes more feasible. We have developed an approach to dose escalation using a combination of prostate brachytherapy followed by external beam radiation therapy in which fiducial markers are placed along with (125)I seeds during transperineal interstitial permanent prostate brachytherapy. These markers serve to verify daily prostate location during the subsequent external beam radiotherapy. Prior to implementing this approach, preliminary studies were performed to test visibility of the markers. Three different (125)I seed models, as well as gold and silver marker seeds were placed within tissue-equivalent phantoms. Images were obtained with conventional x-rays (75-85 kV) and 6 MV photons from a linear accelerator. All (125)I seed models were clearly visible on conventional x-rays but none were seen with 6 MV photons. The gold markers were visible with both energies. The silver markers were visible with conventional x-rays and 6 MV x-rays, but not as clearly as the gold seeds at 6 MV. Subsequently, conventional x-rays, CT scans, and 6 MV port films were obtained in 29 patients in whom fiducial gold marker seeds were implanted into the prostate during (125)I prostate brachytherapy. To address the possibility of "seed migration" within the prostate, CT scans were repeated 5 weeks apart in 14 patients and relative positions of the gold seeds were evaluated. The repeated CT scans showed no change in intraprostatic gold marker location, suggesting minimal migration. The gold seeds were visible with conventional x-rays, CT, and 6 MV port films in all patients. During the course of external beam radiation therapy, the gold markers were visible on routine 6 MV port films and were seen in different locations from film to film suggesting prostate motion. Mean daily displacement was 4-5 mm in the anterior-posterior, and 4-5 mm in superior-inferior dimensions. Left-right displacement appeared less, averaging 2-3 mm. We conclude that implantation of gold marker seeds during prostate brachytherapy represents an easily implemented and practical means of prostate localization during subsequent image-guided external beam radiotherapy. With such markers, conformality of the external beam component can be confidently improved without expensive new equipment.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15270586     DOI: 10.1177/153303460400300405

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  9 in total

1.  Fused radioimmunoscintigraphy for treatment planning.

Authors:  Rodney J Ellis; Deborah A Kaminsky
Journal:  Rev Urol       Date:  2006

2.  The impact of androgen deprivation therapy on setup errors during external beam radiation therapy for prostate cancer.

Authors:  Cem Onal; Yemliha Dolek; Yurday Ozdemir
Journal:  Strahlenther Onkol       Date:  2017-04-13       Impact factor: 3.621

3.  Is it essential to use fiducial markers during cone-beam CT-based radiotherapy for prostate cancer patients?

Authors:  Berna A Yildirim; Cem Onal; Yemliha Dolek
Journal:  Jpn J Radiol       Date:  2016-10-11       Impact factor: 2.374

4.  Qualitative evaluation of fiducial markers for radiotherapy imaging.

Authors:  Maria F Chan; Gil'ad N Cohen; Joseph O Deasy
Journal:  Technol Cancer Res Treat       Date:  2014-09-16

5.  Investigation of dose perturbations and the radiographic visibility of potential fiducials for proton radiation therapy of the prostate.

Authors:  Jessie Y Huang; Wayne D Newhauser; X Ronald Zhu; Andrew K Lee; Rajat J Kudchadker
Journal:  Phys Med Biol       Date:  2011-07-28       Impact factor: 3.609

Review 6.  The physics of proton therapy.

Authors:  Wayne D Newhauser; Rui Zhang
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

7.  Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate.

Authors:  Douglas J Moseley; Elizabeth A White; Kirsty L Wiltshire; Tara Rosewall; Michael B Sharpe; Jeffrey H Siewerdsen; Jean-Pierre Bissonnette; Mary Gospodarowicz; Padraig Warde; Charles N Catton; David A Jaffray
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-03-01       Impact factor: 7.038

8.  Determination of optimal fiducial marker across image-guided radiation therapy (IGRT) modalities: visibility and artifact analysis of gold, carbon, and polymer fiducial markers.

Authors:  Lydia L Handsfield; Ning J Yue; Jinghao Zhou; Ting Chen; Sharad Goyal
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

9.  Comparison of prostate verification with implanted gold markers in tissue surrounding the prostate and pelvic bony anatomy for external beam radiation therapy following low-dose-rate brachytherapy: a prospective clinical trial.

Authors:  Tomoya Kaneda; Toshio Ohashi; Takashi Hanada; Koji Takenaka; Shuichi Nishimura; Masanori Sakayori; Shinya Sutani; Tetsuo Momma; Naoyuki Shigematsu
Journal:  J Radiat Res       Date:  2020-09-08       Impact factor: 2.724

  9 in total