Literature DB >> 15269962

MRI of helium-3 gas in healthy lungs: posture related variations of alveolar size.

Stanislao Fichele1, Neil Woodhouse, Andrew J Swift, Zead Said, Martyn N J Paley, Larry Kasuboski, Gary H Mills, Edwin J R van Beek, Jim M Wild.   

Abstract

PURPOSE: To probe the variation of alveolar size in healthy lung tissue as a function of posture using diffusion-weighted helium-3 hyperpolarized gas imaging.
MATERIALS AND METHODS: Measurements of the helium-3 apparent diffusion coefficient (ADC) were made on six healthy subjects. These were used to show the variation of alveolar size between the lowermost dependent regions of the lung compared to the uppermost regions of the lung in four postures: supine, prone, left-lateral decubitus, and right-lateral decubitus.
RESULTS: The distribution of acinar size in the lungs was found to be heterogeneous, and influenced by lung orientation. In nearly all postures, the ADC was significantly higher in the non-dependent uppermost regions of the lung compared to the dependent lowermost regions of the lung; the greatest variation was found in the left-lateral decubitus position. The difference in ADC between uppermost and lowermost regions was on average 0.012 cm(2)second(-1), which represents 20% of the average ADC value for the whole lung. A systematic decrease in ADC from the apex of the lung to the base was also found, which corresponds to an inherent gradient in alveolar size.
CONCLUSION: The posture dependent variations in ADC were attributed to compression of the parenchyma under its own weight and the mass of the heart.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15269962     DOI: 10.1002/jmri.20104

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  30 in total

1.  Vertical gradients in regional alveolar oxygen tension in supine human lung imaged by hyperpolarized 3He MRI.

Authors:  Hooman Hamedani; Hoora Shaghaghi; Stephen J Kadlecek; Yi Xin; Biao Han; Sarmad Siddiqui; Jennia Rajaei; Masaru Ishii; Milton Rossman; Rahim R Rizi
Journal:  NMR Biomed       Date:  2014-12       Impact factor: 4.044

2.  Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129.

Authors:  John P Mugler; Talissa A Altes; Iulian C Ruset; Isabel M Dregely; Jaime F Mata; G Wilson Miller; Stephen Ketel; Jeffrey Ketel; F William Hersman; Kai Ruppert
Journal:  Proc Natl Acad Sci U S A       Date:  2010-11-22       Impact factor: 11.205

Review 3.  Functional imaging: CT and MRI.

Authors:  Edwin J R van Beek; Eric A Hoffman
Journal:  Clin Chest Med       Date:  2008-03       Impact factor: 2.878

4.  Hyperpolarized 3He MR imaging of the lung: effect of subject immobilization on the occurrence of ventilation defects.

Authors:  Jaime Mata; Talissa Altes; Jeffrey Knake; John Mugler; James Brookeman; Eduard de Lange
Journal:  Acad Radiol       Date:  2008-02       Impact factor: 3.173

5.  A System for Open-Access He Human Lung Imaging at Very Low Field.

Authors:  I C Ruset; L L Tsai; R W Mair; S Patz; M I Hrovat; M S Rosen; I Muradian; J Ng; G P Topulos; J P Butler; R L Walsworth; F W Hersman
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2006       Impact factor: 1.176

6.  Posture-dependent human 3He lung imaging in an open-access MRI system: initial results.

Authors:  Leo L Tsai; Ross W Mair; Chih-Hao Li; Matthew S Rosen; Samuel Patz; Ronald L Walsworth
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

7.  An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging.

Authors:  L L Tsai; R W Mair; M S Rosen; S Patz; R L Walsworth
Journal:  J Magn Reson       Date:  2008-05-24       Impact factor: 2.229

8.  Aerosol deposition characteristics in distal acinar airways under cyclic breathing conditions.

Authors:  Baoshun Ma; Chantal Darquenne
Journal:  J Appl Physiol (1985)       Date:  2011-02-17

9.  In vivo lung morphometry with hyperpolarized (3) He diffusion MRI: reproducibility and the role of diffusion-sensitizing gradient direction.

Authors:  James D Quirk; Yulin V Chang; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2014-04-21       Impact factor: 4.668

10.  Assessment of regional lung function with multivolume (1)H MR imaging in health and obstructive lung disease: comparison with (3)He MR imaging.

Authors:  Francesca Pennati; James D Quirk; Dmitriy A Yablonskiy; Mario Castro; Andrea Aliverti; Jason C Woods
Journal:  Radiology       Date:  2014-06-15       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.