Literature DB >> 15263572

Twin helical undulator beamline for soft X-ray spectroscopy at SPring-8.

Y Saitoh1, T Nakatani, T Matsushita, T Miyahara, M Fujisawa, K Soda, T Muro, S Ueda, H Harada, A Sekiyama, S Imada, H Daimon, S Suga.   

Abstract

A very high resolution soft X-ray beamline, BL25SU, has been designed and is under construction at SPring-8. Completely right or left circularly polarized light is supplied on a common axis of a newly designed twin helical undulator. A helicity modulation up to 10 Hz can be performed using five kicker magnets. The fundamental radiation covers the region 0.5-3 keV. Higher-order radiation is rather weak on the axis. A monochromator with varied-line-spacing plane gratings is installed to cover the region below 1.5 keV. A very high resolution beyond 10(4) is expected for the whole energy region.

Year:  1998        PMID: 15263572     DOI: 10.1107/S090904959701902X

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  2 in total

1.  Development of a soft X-ray angle-resolved photoemission system applicable to 100 µm crystals.

Authors:  Takayuki Muro; Yukako Kato; Tomohiro Matsushita; Toyohiko Kinoshita; Yoshio Watanabe; Hiroyuki Okazaki; Takayoshi Yokoya; Akira Sekiyama; Shigemasa Suga
Journal:  J Synchrotron Radiat       Date:  2011-09-21       Impact factor: 2.616

2.  Soft X-ray angle-resolved photoemission with micro-positioning techniques for metallic V₂O₃.

Authors:  Hidenori Fujiwara; Takayuki Kiss; Yuki K Wakabayashi; Yoshito Nishitani; Takeo Mori; Yuki Nakata; Satoshi Kitayama; Kazuaki Fukushima; Shinji Ikeda; Hiroto Fuchimoto; Yosuke Minowa; Sung-Kwan Mo; Jonathan D Denlinger; James W Allen; Patricia Metcalf; Masaki Imai; Kazuyoshi Yoshimura; Shigemasa Suga; Takayuki Muro; Akira Sekiyama
Journal:  J Synchrotron Radiat       Date:  2015-04-14       Impact factor: 2.616

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.