OBJECTIVE: To investigate the effectiveness of various implants used in experimental deep sclerectomy and to report tissue reactions developed to these implants histopathologically.
MATERIALS AND METHODS: Forty eyes of 40 New Zealand white albino rabbits underwent deep sclerectomy with various implants. The rabbits were divided into four groups; each consisted of 10 eyes. Deep sclerectomy was performed using copolymer materials in group 1, silicone materials in group 2 and chromic catgut suture in group 3. No implants were used in the control group (group 4). Clinical and histopathological examinations were performed to investigate the effectiveness of implants.
RESULTS: Mean preoperative intraocular pressure (IOP) was 14.4 +/- 1.6 mm Hg in group 1, 14.5 +/- 1.8 mm Hg in group 2, 13.8 +/- 1.5 mm Hg in group 3 and 14.5 +/- 1.2 mm Hg in group 4. The final postoperative IOPs were 10.7 +/- 0.9, 10.6 +/- 0.8, 13.5 +/- 1.0, and 14.5 +/- 1.4 mm Hg, respectively. At 2 months, the decrease in IOPs from baseline and the persistence of the filtering bleb were significantly marked in group 1 and group 2 (p < 0.001). Histopathological evaluation revealed that copolymer and silicone materials formed a smooth and regular intrascleral space. There were no foreign body reaction, tissue destruction or fibrosis in group 1 and group 2, but chromic catgut sutures caused severe fibrosis and inflammatory reaction in group 3. Mean histopathologic score of group 1, group 2, group 3 and group 4 was 0.7 +/- 0.5, 0.8 +/- 0.5, 2.4 +/- 0.6, and 0.1 +/- 0.3, respectively.
CONCLUSION: Copolymer or silicone materials may increase the success rate of surgery by maintenance of a large and regular intrascleral space after deep sclerectomy and prevention of collapse of the flap. Copyright 2004 S. Karger AG, Basel

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15258416     DOI: 10.1159/000078618

Source DB:  PubMed          Journal:  Ophthalmologica        ISSN: 0030-3755            Impact factor:   3.250


  4 in total

1.  [A comparison between absorbable and non-resorbable scleral implants in deep sclerectomy (T-Flux and SK-Gel)].

Authors:  A Wiermann; O Zeitz; E Jochim; E T Matthiessen; L Wagenfeld; P Galambos; G Scharioth; N Matthiesen; M Klemm
Journal:  Ophthalmologe       Date:  2007-05       Impact factor: 1.059

2.  In vivo biocompatibility assessment of (PTFE-PVDF-PP) terpolymer-based membrane with potential application for glaucoma treatment.

Authors:  Rafał Leszczynski; Ewa Stodolak; Jarosław Wieczorek; Jolanta Orlowska-Heitzman; Teresa Gumula; Stanislaw Blazewicz
Journal:  J Mater Sci Mater Med       Date:  2010-07-23       Impact factor: 3.896

3.  Intrascleral outflow after deep sclerectomy with absorbable and non-absorbable implants in the rabbit eye.

Authors:  Jakub J Kałużny; Dariusz Grzanka; Halina Wiśniewska; Alicja Niewińska; Bartłomiej J Kałużny; Alina Grzanka
Journal:  Med Sci Monit       Date:  2012-10

4.  Comparison of two prototypes of a magnetically adjustable glaucoma implant in rabbits.

Authors:  Birthe Schwerk; Lisa Harder; Claudia Windhövel; Marion Hewicker-Trautwein; Anna Wagner; Jan-Peter Bach; Lena Carolin Voigt; Ulf Hinze; Boris Chichkov; Heinz Haferkamp; Holger Lubatschowski; Stephan Nikolic; Ingo Nolte
Journal:  PLoS One       Date:  2019-04-11       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.