Literature DB >> 15257250

Use of a stiff guidewire in transjugular liver biopsy in patients with a pronounced angle of the suprahepatic veins.

Andrés de Hoyos1, M Lilia Loredo, Marco A Martínez, Manuel R Gil.   

Abstract

In the performance of a transvascular liver biopsy, the Trucut-type transjugular liver biopsy set is advance over a multipurpose catheter place in the suprahepatic vein. Occasionally there is a sharp bend between the suprahepatic veins and the inferior vein cava and the multipurpose catheter does not provide sufficient support to track the biopsy access set. To deal with this problem we describe the use of a stiff guidewire for an easy introduction of the biopsy set.

Entities:  

Mesh:

Year:  2004        PMID: 15257250

Source DB:  PubMed          Journal:  Ann Hepatol        ISSN: 1665-2681            Impact factor:   2.400


  2 in total

1.  Transjugular liver biopsy: prospective evaluation of the angle formed between the hepatic veins and the vena cava main axis and modification of a semi-automated biopsy device in cases of an unfavorable angle.

Authors:  P Chevallier; F Dausse; F Berthier; M C Saint-Paul; A Denys; P Schnyder; J N Bruneton
Journal:  Eur Radiol       Date:  2006-05-09       Impact factor: 5.315

2.  Role of transjugular liver biopsy in the diagnostic and therapeutic management of patients with severe liver disease.

Authors:  A A Esposito; A Nicolini; D Meregaglia; A Sangiovanni; P Biondetti
Journal:  Radiol Med       Date:  2008-09-09       Impact factor: 3.469

  2 in total