Literature DB >> 15255389

AICRG, Part I: A 6-year multicentered, multidisciplinary clinical study of a new and innovative implant design.

Harold F Morris1, Shigeru Ochi, Patricia Crum, Ira H Orenstein, Sheldon Winkler.   

Abstract

PROBLEM: Repetitive microstrains, which occur at the bone-implant interface during function, can lead to implant loss. In an attempt to improve survival by directing the stresses during function away from the dense cortical bone and toward the resilient trabecular bone, the Ankylos implant was developed with a roughened, progressive thread and a smooth cervical collar. The highly polished collar reduces the stresses in areas of the crestal bone. A precisely machined Morse taper prevents rotation of the abutment on the implant and eliminates the microgap present in many 2-stage implant systems. Clinical studies of other implants at different clinical research centers have demonstrated varying degrees of survival.
PURPOSE: The purpose of this paper was (1) to assess the overall clinical survival of this new implant design and (2) to compare implant stability (ie, Periotest values [PTVs]) over time with other implants.
METHOD: The investigation represented a comprehensive, multicentered, international clinical study conducted over a period of 6 years. It was conducted under an Investigational Device Exemption (IDE) protocol that was reviewed and accepted in the United States by the Food and Drug Administration (FDA). Over 1500 implants were placed and restored, and follow-up data were gathered for a period of up to 3 to 5 years.
RESULTS: Over 44% of the clinical research centers reported no failures (100% survival). A total of 63% of the centers had none or only 1 failure during the study. One center reported 6 failures in 1 patient, which were not related to the implant design. Overall survival for implants in function for 3 to 5 years was 97.5%. Using failure criteria of earlier studies of other implants, 5-year survival was 98.3%. Higher handpiece speeds were associated with an increase in the number of failures. This new design produced a slightly more resilient trabecular bone-implant complex with a difference of about 1 PTV in all bone densities when compared with other implants.
CONCLUSIONS: The following conclusions can be made: (1) the implant design was effective under all clinical conditions; (2) no significant and unexpected complications or risk factors were evident; (3) survival was found to be excellent; and (4) this implant is well suited for use in the restoration of masticatory function and esthetics in patients with missing natural teeth.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15255389     DOI: 10.1563/1548-1336(2004)30<125:APIAYM>2.0.CO;2

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  3 in total

1.  Evaluating systemic administration effect of propranolol on osseointegration around titanium implants: A histomorphometric study in dogs.

Authors:  Mohammad Tavakoli; Mohammad Jafari Farshami; Nakisa Torabinia; Jaber Yaghini; Samaneh Shams
Journal:  Dent Res J (Isfahan)       Date:  2022-04-27

Review 2.  Morse taper dental implants and platform switching: The new paradigm in oral implantology.

Authors:  José Paulo Macedo; Jorge Pereira; Brendan R Vahey; Bruno Henriques; Cesar A M Benfatti; Ricardo S Magini; José López-López; Júlio C M Souza
Journal:  Eur J Dent       Date:  2016 Jan-Mar

3.  Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures.

Authors:  Hye Won Shim; Byoung-Eun Yang
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.