Monitoring depth of anaesthesia: is it worth the effort?

V Bonhomme1, P Hans.   

Abstract

In this review paper, the authors critically analyse the use of a number of depth of anaesthesia monitors in light of the most recent literature and their own clinical experience. There appears to be increasing evidence that anaesthesia depth monitors reduce the incidence of unexpected intraoperative awareness and also that they improve the quality of anaesthesia. Proper use of these monitors necessitates background knowledge about the physiology of the loss of consciousness, the type of variable recorded and processed by the monitoring devices, the factors that might interfere with recording and the limits of use. The information provided by anaesthesia depth monitors is detailed and relationships with clinical practice are established to provide the reader with key features for optimal use of those monitors and correct interpretation of data. Practitioners and patient's knowledge and expectations regarding this matter, as well as the cost-benefit relationship are also discussed.

Entities:  

Mesh:

Year:  2004        PMID: 15248620     DOI: 10.1017/s0265021504006027

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  6 in total

Review 1.  Neurophysiological investigation of hepatic encephalopathy.

Authors:  Piero Amodio; Angelo Gatta
Journal:  Metab Brain Dis       Date:  2005-12       Impact factor: 3.584

Review 2.  Clinical neurophysiology of hepatic encephalopathy.

Authors:  Piero Amodio; Sara Montagnese
Journal:  J Clin Exp Hepatol       Date:  2014-08-03

3.  Efficacy of the bispectral index and Observer's Assessment of Alertness/Sedation Scale in monitoring sedation during spinal anesthesia: A randomized clinical trial.

Authors:  Tae Wan Lim; Yi Hwa Choi; Jong Yeop Kim; Jong Bum Choi; Soo Kyung Lee; Eun Ji Youn; Jun Suck Lee
Journal:  J Int Med Res       Date:  2019-12-25       Impact factor: 1.671

4.  The role of entropy monitoring in reducing propofol requirements during open heart surgeries. A prospective randomized study.

Authors:  Ahmed Said Elgebaly; Mona B El Mourad; Sameh Mohamad Fathy
Journal:  Ann Card Anaesth       Date:  2020 Jul-Sep

5.  Fat embolism among patients with hip and long bone fractures in Albania.

Authors:  Elida Hysa
Journal:  Mater Sociomed       Date:  2012

6.  The Alaris auditory evoked potential monitor as an indicator of seizure inducibility and duration during electroconvulsive therapy: an observational study.

Authors:  Hsing-Hao Huang; Chun-Yu Wu; Feng-Sheng Lin; Yi-Ping Wang; Wei-Zen Sun; Chih-Peng Lin; Shou-Zen Fan
Journal:  BMC Anesthesiol       Date:  2014-05-13       Impact factor: 2.217

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.