Literature DB >> 15248587

Application of discrete data consistency conditions for selecting regularization parameters in PET attenuation map reconstruction.

Vladimir Y Panin1, Frank Kehren, James J Hamill, Christian Michel.   

Abstract

Simultaneous emission and transmission measurement is appealing in PET due to the matching of geometrical conditions between emission and transmission and reduced acquisition time for the study. A potential problem remains: when transmission statistics are low, attenuation correction could be very noisy. Although noise in the attenuation map can be controlled through regularization during statistical reconstruction, the selection of regularization parameters is usually empirical. In this paper, we investigate the use of discrete data consistency conditions (DDCC) to optimally select one or two regularization parameters. The advantages of the method are that the reconstructed attenuation map is consistent with the emission data and that it accounts for particularity in the emission reconstruction algorithm and acquisition geometry. The methodology is validated using a computer-generated whole-body phantom for both emission and transmission, neglecting random events and scattered radiation. MAP-TR was used for attenuation map reconstruction, while 3D OS-EM is used for estimating the emission image. The estimation of regularization parameters depends on the resolution of the emission image controlled by the number of iterations in OS-EM. The computer simulation shows that, on one hand, DDCC regularized attenuation map reduces propagation of the transmission scan noise to the emission image, while on the other hand DDCC prevents excessive attenuation map smoothing that could result in resolution mismatch artefacts between emission and transmission.

Mesh:

Year:  2004        PMID: 15248587     DOI: 10.1088/0031-9155/49/11/021

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Joint estimation of activity image and attenuation sinogram using time-of-flight positron emission tomography data consistency condition filtering.

Authors:  Quanzheng Li; Hao Li; Kyungsang Kim; Georges El Fakhri
Journal:  J Med Imaging (Bellingham)       Date:  2017-04-26

3.  Zero-Extra-Dose PET Delayed Imaging with Data-Driven Attenuation Correction Estimation.

Authors:  Lifang Pang; Wentao Zhu; Yun Dong; Yang Lv; Hongcheng Shi
Journal:  Mol Imaging Biol       Date:  2019-02       Impact factor: 3.488

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.