Literature DB >> 15246523

Low-dose CT of the thorax in cancer follow-up.

Takayuki Yamada1, Shuichi Ono, Masahiro Tsuboi, Haruo Saito, Akihiro Sato, Toshio Matsuhashi, Tadashi Ishibashi, Shoki Takahashi.   

Abstract

PURPOSE: To evaluate the quality of low-dose computed tomography (CT) images in the follow-up of cancer patients.
MATERIALS AND METHODS: We selected patients with urogenital (n = 7) or esophageal cancer (n = 13) who were attending routine follow-up between April and July 2001. After water and chest phantom studies to decide the scan parameters, postcontrast low-dose CT scans were obtained at 60 mA (45 mA s) with a smoothing kernel. Three radiologists reviewed the CT scans of the thorax independently for overall image quality and anatomic detail in both mediastinal and lung windows. They subjectively rated the images on a four-point scale (0: poor, 1: fair, 2: good, 3: excellent) according to graininess and sharpness.
RESULTS: The average score of the low-dose CT for the lung window was 2.85, which was equivalent to control images. The average score for the mediastinal window was 1.77, which was lower than that of the control CT scan (2.62, P < 0.001) and almost identical to that of the chest phantom experiment. Nine of the 20 cases had abnormal findings; low-dose CT scans depicted them well and offered sufficient information for diagnosis. The radiation exposure was reduced by about half.
CONCLUSION: The image quality of low-dose thoracic CT was satisfactory for both mediastinal and lung windows in the follow-up of cancer patients.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15246523     DOI: 10.1016/j.ejrad.2003.09.017

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  6 in total

1.  Thoracic lymph node delineation at dose-reduced (1 mSv) dose-modulated contrast enhanced MDCT: a retrospective pilot study.

Authors:  Marco Paolini; Kathrin Wirth; Amanda Tufman; Maximilian Reiser; Rudolf M Huber; Ullrich G Mueller-Lisse
Journal:  Radiol Med       Date:  2016-05-06       Impact factor: 3.469

2.  Less radiation, same quality: contrast-enhanced multi-detector computed tomography investigation of thoracic lymph nodes with one milli-sievert.

Authors:  Ullrich G Mueller-Lisse; Larissa Marwitz; Amanda Tufman; Rudolf M Huber; Hanna A Zimmermann; Annemarie Walterham; Stefan Wirth; Marco Paolini
Journal:  Radiol Med       Date:  2018-06-30       Impact factor: 3.469

3.  Low-dose chest computed tomography for quantitative and visual anatomical analysis in patients with acute respiratory distress syndrome.

Authors:  Davide Chiumello; Thomas Langer; Vittoria Vecchi; Simone Luoni; Andrea Colombo; Matteo Brioni; Sara Froio; Irene Cigada; Silvia Coppola; Alessandro Protti; Marco Lazzerini; Luciano Gattinoni
Journal:  Intensive Care Med       Date:  2014-03-20       Impact factor: 17.440

4.  Optimal dose levels in screening chest CT for unimpaired detection and volumetry of lung nodules, with and without computer assisted detection at minimal patient radiation.

Authors:  Andreas Christe; Zsolt Szucs-Farkas; Adrian Huber; Philipp Steiger; Lars Leidolt; Justus E Roos; Johannes Heverhagen; Lukas Ebner
Journal:  PLoS One       Date:  2013-12-26       Impact factor: 3.240

5.  Radiation dose reduction of chest CT with iterative reconstruction in image space - Part I: studies on image quality using dual source CT.

Authors:  Hye Jeon Hwang; Joon Beom Seo; Jin Seong Lee; Jae-Woo Song; Song Soo Kim; Hyun Joo Lee; Chae Hun Lim
Journal:  Korean J Radiol       Date:  2012-10-12       Impact factor: 3.500

6.  Low dose chest CT protocol (50 mAs) as a routine protocol for comprehensive assessment of intrathoracic abnormality.

Authors:  Takeshi Kubo; Yoshiharu Ohno; Mizuki Nishino; Pei-Jan Lin; Shiva Gautam; Hans-Ulrich Kauczor; Hiroto Hatabu
Journal:  Eur J Radiol Open       Date:  2016-04-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.