Effect of high intensity vs. soft-start halogen irradiation on light-cured resin-based composites. Part II: Hardness and solubility.

Norbert Hofmann1, Tanja Markert, Burkard Hugo, Bernd Klaiber.   

Abstract

PURPOSE: To determine hardness and solubility of light-cured resin-based composites after high intensity vs. soft-start quartz tungsten halogen irradiation.
METHODS: Knoop hardness of resin-based composite specimens was measured at 1.5 mm depth after dry storage for 24 hours at 37 degrees C so as to indirectly evaluate degree of cure. Solubility was determined gravimetrically by extraction of post-cured (24 hours, 37 degrees C) specimens in 50 wt% methanol for 72 hours. Four hybrid (Filtek Z250, Herculite, Solitaire 2, Tetric Ceram), an inhomogeneously filled hybrid (InTen-S) and a microfilled (Filtek A110, formerly Silux Plus) composite were cured using the quartz tungsten halogen units Astralis 10 and Optilux 501 in the high intensity (Astralis 10 High Power: 10 seconds @ 1300 mW/cm2; Optilux Boost: 10 seconds @ 1140 mW/cm2) or soft-start modes (Astralis 10 Pulse: increase to 700 mW/cm2 within 10 seconds, three periods of 2 seconds @ 1300 mW/cm2 alternating with two periods of 2 seconds @ 700 mW/cm2; Optilux Ramp: exponential increase within 10 seconds, followed by 10 seconds @ 1140mW/cm2).
RESULTS: For the fast curing composites Z250, Tetric Ceram and InTen-S, equivalent hardness was observed after 10 seconds of high intensity and 20 seconds of soft-start irradiation. For the slower curing composites Herculite, Solitaire 2 and A110, the soft-start protocols produced higher hardness values. Regarding solubility however, the superiority of soft-start irradiation was also seen for Tetric Ceram and InTen-S. The lowest solubility was observed for InTen-S, followed by Z250, whereas Herculite and Solitaire 2 scored highest for this parameter.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15241908

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  3 in total

1.  Is the soft-start polymerisation concept still relevant for modern curing units?

Authors:  Nicoleta Ilie; Esther Jelen; Reinhard Hickel
Journal:  Clin Oral Investig       Date:  2009-11-24       Impact factor: 3.573

2.  Effects of light curing method and exposure time on mechanical properties of resin based dental materials.

Authors:  A Riza Alpöz; Fahinur Ertugrul; Dilsah Cogulu; Asli Topaloglu Ak; Metin Tanoglu; Elçin Kaya
Journal:  Eur J Dent       Date:  2008-01

3.  Thermal rise during photopolymerization and degree of conversion of bulk fill and conventional resin composites.

Authors:  Sayed Mostafa Mousavinasab; Zahra Taromi; Elham Zajkani
Journal:  Dent Res J (Isfahan)       Date:  2020-08-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.