Literature DB >> 15241646

Stroke volume monitored by modeling flow from finger arterial pressure waves mirrors blood volume withdrawn by phlebotomy.

Pascal Leonetti1, Françoise Audat, Arlette Girard, Dominique Laude, François Lefrère, Jean-Luc Elghozi.   

Abstract

Rate-controlled blood withdrawal was used to reduce cardiac preload and consequently stroke volume in patients with normal cardiac function. Twelve patients with asymptomatic hereditary hemochromatosis, undergoing regular phlebotomy therapy, volunteered for the study. An average volume of 375 ml was withdrawn in an average period of 6.4 min. Finger pressure was continuously measured by a Finometer device which includes the Beatscope software for deriving the stroke volume from the blood pressure waveform. Blood withdrawal resulted in reduction of the stroke volume estimates (from 94.0 +/- 5.2 to 80.7 +/- 5.3, P < 0.05) together with a reduced pulse pressure (from 53.0 +/- 3.5 to 47.1 +/- 3.2, P < 0.05). No significant changes in heart rate (75.2 +/- 3.7 versus 78.3 +/- 4.5 beats/min) were observed. Calculated cardiac output was reduced while calculated total peripheral resistance was elevated after blood withdrawal. Beat-to-beat analysis demonstrated a significant linear regression between most of the hemodynamic indices and the volume withdrawn. The highest correlation coefficients were found for the stroke volume (0.88 +/- 0.01, P < 0.001) and the pulse pressure (0.80 +/- 0.04, P < 0.001) corresponding also to the highest slopes for the lines relating these measures to the relative blood volume withdrawn. The non-invasive estimation of finger blood pressure can be used to derive simple on-line indices (pulse pressure, stroke volume using the Modelflow) of cardiac preload, which are of major interest in the monitoring of cardiovascular status.

Entities:  

Mesh:

Year:  2004        PMID: 15241646     DOI: 10.1007/s10286-004-0191-1

Source DB:  PubMed          Journal:  Clin Auton Res        ISSN: 0959-9851            Impact factor:   4.435


  15 in total

1.  Validation of lower body negative pressure as an experimental model of hemorrhage.

Authors:  Carmen Hinojosa-Laborde; Robert E Shade; Gary W Muniz; Cassondra Bauer; Kathleen A Goei; Heather F Pidcoke; Kevin K Chung; Andrew P Cap; Victor A Convertino
Journal:  J Appl Physiol (1985)       Date:  2013-12-19

2.  Compression leggings modestly affect cardiovascular but not cerebrovascular responses to heat and orthostatic stress in young and older adults.

Authors:  Rebekah Ann Isabel Lucas; Philip N Ainslie; Shawnda A Morrison; James D Cotter
Journal:  Age (Dordr)       Date:  2011-04-28

3.  Tilt testing with combined lower body negative pressure: a "gold standard" for measuring orthostatic tolerance.

Authors:  Clare L Protheroe; Henrike Rianne J C Ravensbergen; Jessica A Inskip; Victoria E Claydon
Journal:  J Vis Exp       Date:  2013-03-21       Impact factor: 1.355

4.  Cardiac output and sympathetic vasoconstrictor responses during upright tilt to presyncope in healthy humans.

Authors:  Qi Fu; Bart Verheyden; Wouter Wieling; Benjamin D Levine
Journal:  J Physiol       Date:  2012-02-13       Impact factor: 5.182

5.  Integrated Compensatory Responses in a Human Model of Hemorrhage.

Authors:  Victor A Convertino; Carmen Hinojosa-Laborde; Gary W Muniz; Robert Carter
Journal:  J Vis Exp       Date:  2016-11-20       Impact factor: 1.355

6.  Spectral analysis of respiratory-related hemodynamic variables in simulated hypovolemia: a study in healthy volunteers with spontaneous breathing using a paced breathing activity.

Authors:  Won Jung Shin; Jae Moon Choi; Yu Gyeong Kong; Jun Gol Song; Young Kug Kim; Gyu Sam Hwang
Journal:  Korean J Anesthesiol       Date:  2010-06-23

7.  Cardiac stroke volume variability measured non-invasively by three methods for detection of central hypovolemia in healthy humans.

Authors:  Nathalie Linn Anikken Holme; Erling Bekkestad Rein; Maja Elstad
Journal:  Eur J Appl Physiol       Date:  2016-09-10       Impact factor: 3.078

8.  Tuba players reproduce a Valsalva maneuver while playing high notes.

Authors:  Jean-Luc Elghozi; Arlette Girard; Philippe Fritsch; Dominique Laude; Jean-Luc Petitprez
Journal:  Clin Auton Res       Date:  2008-04       Impact factor: 4.435

9.  Reductions in central venous pressure by lower body negative pressure or blood loss elicit similar hemodynamic responses.

Authors:  Blair D Johnson; Noud van Helmond; Timothy B Curry; Camille M van Buskirk; Victor A Convertino; Michael J Joyner
Journal:  J Appl Physiol (1985)       Date:  2014-05-29

10.  Influence of upper body position on middle cerebral artery blood velocity during continuous positive airway pressure breathing.

Authors:  J Højlund Rasmussen; T Mantoni; B Belhage; F C Pott
Journal:  Eur J Appl Physiol       Date:  2007-07-19       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.