Literature DB >> 15241173

Microspheres accurately predict regional bone blood flow.

H Anetzberger1, E Thein, M Becker, B Zwissler, K Messmer.   

Abstract

Even though the microsphere method frequently is used to determinate bone blood flow, validation of this technique for bone blood flow measurement is incomplete. The method is based on the principle that injected microspheres are distributed with the arterial blood and trapped in the capillaries because of their diameter (15 microm). The number of spheres lodged in an organ is proportional to its blood flow. The number of radioactive or fluorescent microspheres in a specific organ is determined indirectly by measuring radioactivity or fluorescence intensity in the organ. In this study the reliability and precision of the microsphere method for determining bone blood flow was established using radioactive and fluorescent microspheres. Six female, anesthetized New Zealand rabbits received left ventricular injections of pairs of fluorescent and/or radioactive microspheres. The humerus, femur, and tibia were dissected in a standardized manner and blood flow was determined in each sample. Comparison of relative blood flow values showed an excellent correlation between radioactive and fluorescent microspheres. The percentage difference and variation between two simultaneously injected sets of microspheres was minimal for radioactive microspheres (0.8% +/- 9.6%) and for fluorescent microspheres (0.2% +/- 11.4%). Regional bone blood flow in different regions of the femur, tibia, or humerus ranged from 2.2-28.1 mL/minute/100 g, but there was no significant difference between right and left bone samples of the same region after repeated measurement. Radioactive and fluorescent microspheres allow precise determination of regional bone blood flow.

Entities:  

Mesh:

Year:  2004        PMID: 15241173     DOI: 10.1097/01.blo.0000128281.67589.b4

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

1.  Non-invasive continuous estimation of blood flow changes in human patellar bone.

Authors:  Jan Näslund; Jonas Pettersson; Thomas Lundeberg; Dag Linnarsson; Lars-Göran Lindberg
Journal:  Med Biol Eng Comput       Date:  2006-06-03       Impact factor: 2.602

2.  Temperature regulates limb length in homeotherms by directly modulating cartilage growth.

Authors:  Maria A Serrat; Donna King; C Owen Lovejoy
Journal:  Proc Natl Acad Sci U S A       Date:  2008-12-01       Impact factor: 11.205

3.  Measuring bone blood supply in mice using fluorescent microspheres.

Authors:  Maria A Serrat
Journal:  Nat Protoc       Date:  2009-11-05       Impact factor: 13.491

4.  Bone-Specific Metabolism of Dietary Polyphenols in Resorptive Bone Diseases.

Authors:  Andrew G Kunihiro; Paula B Luis; Jennifer B Frye; Wade Chew; H H Chow; Claus Schneider; Janet L Funk
Journal:  Mol Nutr Food Res       Date:  2020-06-25       Impact factor: 5.914

Review 5.  Bone Cell Bioenergetics and Skeletal Energy Homeostasis.

Authors:  Ryan C Riddle; Thomas L Clemens
Journal:  Physiol Rev       Date:  2017-04       Impact factor: 37.312

6.  Exenatide Improves Bone Quality in a Murine Model of Genetically Inherited Type 2 Diabetes Mellitus.

Authors:  Marie Pereira; Stephanie Gohin; Jean-Paul Roux; Amy Fisher; Mark E Cleasby; Guillaume Mabilleau; Chantal Chenu
Journal:  Front Endocrinol (Lausanne)       Date:  2017-11-20       Impact factor: 5.555

7.  Assessment of regional bone tissue perfusion in rats using fluorescent microspheres.

Authors:  Mohammad W Aref; Ethan Akans; Matthew R Allen
Journal:  Bone Rep       Date:  2017-04-26

8.  SPECT/CT-plethysmography--non-invasive quantitation of bone and soft tissue blood flow.

Authors:  Lior Dayan; Zohar Keidar; Ora Israel; Victor Milloul; Johnathan Sachs; Giris Jacob
Journal:  J Orthop Surg Res       Date:  2008-08-18       Impact factor: 2.359

9.  The anabolic action of intermittent parathyroid hormone on cortical bone depends partly on its ability to induce nitric oxide-mediated vasorelaxation in BALB/c mice.

Authors:  S Gohin; A Carriero; C Chenu; A A Pitsillides; T R Arnett; M Marenzana
Journal:  Cell Biochem Funct       Date:  2016-02-01       Impact factor: 3.685

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.