PURPOSE: To measure the accuracy of laser-guided punctures and to evaluate the usefulness of the developed laser-guided system.
MATERIAL AND METHODS: The study included 67 patients referred for computed-tomography-guided puncture. The majority of the punctured lesions were located in the chest (28 patients) or abdomen (19 patients). The mean diameter of the lesion was 3.1 cm, and the mean path length was 6.8 cm. The laser guide was movable along a horizontal or vertical rail and not physically connected to the CT unit. The angle of insertion was entered manually into the display of the unit by the interventional radiologist. A prospective multicenter trial was carried out.
RESULTS: A mean of 1.1 needle passes were necessary to reach the target, and in 55 (84.6%) of the patients the target was reached on the first needle pass. The mean deviation of the needle from the preselected angle was 1.8 degrees. The mean targeting time (from the initial localizing scan until the needle was in the target) was 15.6 min. In every case, both the usefulness and the ease of use of the laser guidance system were subjectively evaluated on a 5-point scale; the mean usefulness score was 4.5, while the mean ease of use score was 4.7.
CONCLUSION: Different users at four different centers found the laser guidance system useful and easy to use. A high level of accuracy of the puncture angle was obtained in most cases.

Entities:  

Mesh:

Year:  2004        PMID: 15239427     DOI: 10.1080/02841850410005039

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  6 in total

1.  Laser-guided percutaneous kidney access with the Uro Dyna-CT: first experience of three-dimensional puncture planning with an ex vivo model.

Authors:  M Ritter; M-C Rassweiler; A Häcker; M S Michel
Journal:  World J Urol       Date:  2012-03-04       Impact factor: 4.226

2.  Laser-guided computed tomography puncture system: simulation experiments using artificial phantom lesions and preliminary clinical experience.

Authors:  Norihisa Nitta; Masashi Takahashi; Toyohiko Tanaka; Ryutaro Takazakura; Yoko Sakashita; Akira Furukawa; Kiyoshi Murata; Keiji Shimoyama
Journal:  Radiat Med       Date:  2007-05-28

3.  [New puncture techniques in urology using 3D-assisted imaging].

Authors:  M Ritter; M-C Rassweiler; J J Rassweiler; M S Michel
Journal:  Urologe A       Date:  2012-12       Impact factor: 0.639

4.  Efficacy of Shadow-Based Needle Positioning System in Performing CT Image-Guided Percutaneous Biopsy of Lung Lesions: Our Initial Experience.

Authors:  Shyamkumar N Keshava; Vinu Moses; Aswin Padmanabhan
Journal:  Indian J Radiol Imaging       Date:  2022-04-27

5.  Comparison of a Robotic and Patient-Mounted Device for CT-Guided Needle Placement: A Phantom Study.

Authors:  Yannick Scharll; Alexander Mitteregger; Gregor Laimer; Christoph Schwabl; Peter Schullian; Reto Bale
Journal:  J Clin Med       Date:  2022-06-28       Impact factor: 4.964

6.  Laser-guided cervical selective nerve root block with the Dyna-CT: initial experience of three-dimensional puncture planning with an ex-vivo model.

Authors:  Miriam I E Freundt; Manuel Ritter; Mansour Al-Zghloul; Christoph Groden; Hans U Kerl
Journal:  PLoS One       Date:  2013-07-19       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.