Accuracy of ultrasound in localization of breast boost field.

Jolie Ringash1, Timothy Whelan, Elizabeth Elliott, Terry Minuk, Kenneth Sanders, Himu Lukka, Harold Reiter.   

Abstract

BACKGROUND AND
PURPOSE: To prospectively compare diagnostic ultrasound to the 'gold standard' of surgical clips for localization of the lumpectomy site for electron boost irradiation. PATIENTS AND METHODS: Consecutive breast cancer patients referred following lumpectomy underwent diagnostic ultrasound in radiation treatment position 21-100 days post-surgery. All patients had 3-6 surgical clips defining the excision cavity. The site was marked on the skin and depth was measured. Target depth was the deepest aspect of the cavity plus a 1 cm deep margin. Treatment fields were prescribed with a 2 cm margin on the cavity, and electron energy was chosen to cover the target depth. Surgical clip position was assessed on orthogonal simulator films.
RESULTS: Localizations were performed in 54 breasts (52 women). The mean interval post-surgery was 53 (SD 17) days. Overall, 35/54 (65%) of localizations were adequate, 15/54 (28%) were marginal and 4/54 (7%) were inadequate. Regression showed that lower patient weight (r=-0.37, P=0.006) predicted adequacy of localization, with better accuracy in lighter women.
CONCLUSIONS: The accuracy rate for ultrasound exceeds the 20-50% reported for clinical localization. Diagnostic ultrasound may be used to improve the accuracy when surgical clips are not present.

Entities:  

Mesh:

Year:  2004        PMID: 15236875     DOI: 10.1016/j.radonc.2004.03.013

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  3 in total

1.  3-D conformal photon boost in the treatment of early stage breast cancer: four year follow up results.

Authors:  Arpad Kovacs; Ferenc Lakosi; Gabor Liposits; Gabor Toller; Janaki Hadjiev; Csaba Vandulek; Norbert Walter; Csaba Glavak; Gergely Antal; Akos Horvath; Imre Repa; Peter Bogner
Journal:  Pathol Oncol Res       Date:  2010-04-11       Impact factor: 3.201

2.  Comparison of photon with electron boost in treatment of early stage breast cancer.

Authors:  Arpad Kovacs; Janaki Hadjiev; Ferenc Lakosi; Csaba Glavak; Gergely Antal; Peter Bogner; Akos Horvath; Imre Repa
Journal:  Pathol Oncol Res       Date:  2008-03-15       Impact factor: 3.201

3.  Image guidance using 3D-ultrasound (3D-US) for daily positioning of lumpectomy cavity for boost irradiation.

Authors:  Manjeet Chadha; Amy Young; Charles Geraghty; Robert Masino; Louis Harrison
Journal:  Radiat Oncol       Date:  2011-05-09       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.