Cardiopulmonary responses to the tracheobronchial suction with a fiberoptic bronchoscope during and after anesthesia.

T Arai1, Y Hatano, M Imamura, K Mori.   

Abstract

The cardiopulmonary responses to endobronchial suction with a fiberoptic bronchoscope (FOB suction) during and after anesthesia were compared in 12 patients underwent elective surgeries. FOB suction for 1 mm was performed during enflurane anesthesia (1.5% enflurane in oxygen) with muscle relaxant (anesthetized stage) and after anesthesia during spontaneously breathing of oxygen (awake stage). FOB suction lowered PaO2 to a greater extent in the awake than in the anesthetized stage. Mean PaO2 decreased from 414 to 111 torr in the awake and from 447 to 333 in the anesthetized stage. During suction, PaCO2 slightly increased in both stages. In response to FOB suction, heart rate increased significantly in the awake stage (P < 0.001), while mean blood pressure increased significantly in the anesthetized stage (P < 0.01). These findings indicate that the cardiopulmonary responses to FOB suction for 1 min during and after anesthesia differed. The procedure might be less dangerous during anesthesia.

Entities:  

Year:  1989        PMID: 15236036     DOI: 10.1007/s0054090030183

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  14 in total

1.  The rate of rise of PaCO2 in the apneic anesthetized patient.

Authors:  E I EGER; J W SEVERINGHAUS
Journal:  Anesthesiology       Date:  1961 May-Jun       Impact factor: 7.892

2.  Deaths and complications associated with fiberoptic bronchoscopy.

Authors:  P M Suratt; J F Smiddy; B Gruber
Journal:  Chest       Date:  1976-06       Impact factor: 9.410

3.  Reflex circulatory responses to direct laryngoscopy and tracheal intubation performed during general anesthesia.

Authors:  B D KING; L C HARRIS; F E GREIFENSTEIN; J D ELDER; R D DRIPPS
Journal:  Anesthesiology       Date:  1951-09       Impact factor: 7.892

4.  Ventilation-perfusion alterations induced by fiberoptic bronchoscopy.

Authors:  B B Brach; G G Escano; J H Harrell; K M Moser
Journal:  Chest       Date:  1976-03       Impact factor: 9.410

5.  Cardiopulmonary changes during flexible fiberoptic bronchoscopy.

Authors:  G P Randazzo; A R Wilson
Journal:  Respiration       Date:  1976       Impact factor: 3.580

6.  Normalizing low arterial CO 2 tension during mechanical ventilation.

Authors:  H Breivik; A Grenvik; E Millen; P Safar
Journal:  Chest       Date:  1973-04       Impact factor: 9.410

7.  Arterial hypoxemia induced by fiberoptic bronchoscopy.

Authors:  R E Albertini; J H Harrell; N Kurihara; K M Moser
Journal:  JAMA       Date:  1974 Dec 23-30       Impact factor: 56.272

8.  Pathogenesis and prevention of tracheobronchial damage with suction procedures.

Authors:  M A Sackner; J F Landa; N Greeneltch; M J Robinson
Journal:  Chest       Date:  1973-09       Impact factor: 9.410

9.  Avoidance of hypoxemia during endotracheal suction.

Authors:  B J Urban; S W Weitzner
Journal:  Anesthesiology       Date:  1969-11       Impact factor: 7.892

10.  Muscular, bronchomotor and cardiovascular reflexes elicited by mechanical stimulation of the respiratory tract.

Authors:  Z Tomori; J G Widdicombe
Journal:  J Physiol       Date:  1969-01       Impact factor: 5.182

View more