[Contact dermatitis from polyacrylate in TENS electrode].

F Weber-Muller1, S Reichert-Penetrat, J-L Schmutz, A Barbaud.   

Abstract

INTRODUCTION: Transcutaneous electric nerve stimulation (TENS) is useful for many chronic pains. It induces few serious side effects, but skin reactions are not rare. We report on two cases of contact dermatitis due to TENS electrodes by sensitization to the acrylate in TENS conductive gel. CASE REPORTS: A 50 year-old man suffered from post-traumatic lumbar pair. He developed eczematous lesions on the sites where the TENS electrodes were applied. Patch tests were positive with the TENS gel, with ethylene glycol dimethylacrylate (2 p. 100 petrolatum) and ethyl-acrylate (2 p. 100 petrolatum) on day 2 and 4 readings. A 54 Year-old man had a paralysis of the foot elevator following rupture of an aneurysm. After 2 months, he had an eczema on the sites where the TENS electrodes were applied. Patch tests were negative with the TENS electrodes but positive with 2-hydroxyethyl acrylate (0.1 p. 100 petrolatum), triethyleneglycol diacrylate (0.1 p. 100 petrolatum), 2-hydroxyethyl methacrylate (2 p. 100 petrolatum) and 2-hydroxypropyl methacrylate (2 p. 100 petrolatum) on day 2 and 4 readings. DISCUSSION: TENS transmits small electrical currents through the skin that induce the depolarization of the affected sensory nerve endings. They have few serious side effects but skin reactions such as irritation, burns or allergy to propylene glycol in the electrode gel, to the rubber of the electrodes (mercaptobenzothiazole) or to the metallic part of the electrodes, i.e. nickel, are not uncommon. To our knowledge, only one case of an allergy to the polyacrylates of TENS electrode gel has been previously reported in the literature. We emphasize that acrylate could be the main sensitizer in the more recently commercialized TENS electrodes and will propose alternative ways of treating patients sensitized to acrylate and who require treatment with TENS.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15235538     DOI: 10.1016/s0151-9638(04)93644-7

Source DB:  PubMed          Journal:  Ann Dermatol Venereol        ISSN: 0151-9638            Impact factor:   0.777


  2 in total

1.  ELECTROPHYSICAL AGENTS - Contraindications And Precautions: An Evidence-Based Approach To Clinical Decision Making In Physical Therapy.

Authors: 
Journal:  Physiother Can       Date:  2011-01-05       Impact factor: 1.037

2.  Safety and patients' satisfaction of transcutaneous supraorbital neurostimulation (tSNS) with the Cefaly® device in headache treatment: a survey of 2,313 headache sufferers in the general population.

Authors:  Delphine Magis; Simona Sava; Tullia Sasso d'Elia; Roberta Baschi; Jean Schoenen
Journal:  J Headache Pain       Date:  2013-12-01       Impact factor: 7.277

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.