Literature DB >> 15235200

Imaging using Tc99m-tetrofosmin for the detection of the recurrence of brain tumour: a comparative study with Tc99m-glucoheptonate.

Sukanta Barai1, G P Bandopadhayaya, P K Julka, A Malhotra, C S Bal, H Dhanpathi.   

Abstract

BACKGROUND: In the past "blood-brain barrier" agents such as Tc99m-glucoheptonate were routinely used for the diagnosis of brain tumours. Of late, agents used for studying myocardial perfusion namely, Tc99m-tetrofosmin, Thallium-201, and Tc99m-sestamibi have replaced the "blood-brain barrier agents " when imaging is undertaken for the detection of the recurrence of brain tumours. However, the incremental diagnostic information provided by Tc99m-tetrofosmin when compared with a blood brain barrier agent in the diagnosis of recurrent brain tumour has not been evaluated till date. AIMS: The study was carried out to substantiate whether Tc99m-tetrofosmin provides any incremental diagnostic information not provided by the blood brain barrier agent Tc99m-glucoheptonate.
MATERIAL AND METHODS: Brain SPECT scans were performed using Tc99m-tetrofosmin and Tc99m-glucoheptonate in 126 patients of recurrent brain tumour. Bio-distribution and uptake properties of both the tracers were analysed by measuring relative uptake of both the tracers in tumour compared to background (T/B ratio), nasopharynx (T/N ratio) and scalp (T/S ratio). STATISTICAL ANALYSIS: Descriptive statistics were calculated for each variable. Pearson's correlation coefficient was applied to see agreement of the continuous variables. Paired t test was used to evaluate the difference between two means.
RESULTS: Uptake properties of both the tracers were analysed in 105 patients in whom both Tc99m-tetrofosmin and Tc99m-glucoheptonate showed concentration. The remaining 21 patients in whom the tumour mass did not show Tc99m-tetrofosmin concentration were excluded from the study. Mean T/B ratio, T/N ratio and T/S ratio was 5.83 + 2.09 and 5.99 + 2.26, 0.53 + 0.21 and 0.55 + 0.22 and 1.11 + 0.60 and 1.26 + 0.52 for Tc99m-tetrofosmin and Tc99m-glucoheptonate respectively. No statistically significant difference between T/B ratio and T/N ratio of Tc99m-tetrofosmin and Tc99m-glucoheptonate was found; p values were 0.25 and 0.83 respectively. However there was significant difference (P=0.006) between the T/S ratio of Tc99m-tetrofosmin and that of Tc99m-glucoheptonate.
CONCLUSION: Tc99m-tetrofosmin does not provide any incremental diagnostic information not provided by the blood brain barrier agent Tc99m-glucoheptonate.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15235200

Source DB:  PubMed          Journal:  J Postgrad Med        ISSN: 0022-3859            Impact factor:   1.476


  4 in total

Review 1.  Differentiating tumor recurrence from treatment necrosis: a review of neuro-oncologic imaging strategies.

Authors:  Nishant Verma; Matthew C Cowperthwaite; Mark G Burnett; Mia K Markey
Journal:  Neuro Oncol       Date:  2013-01-16       Impact factor: 12.300

Review 2.  Glioma recurrence versus radiation necrosis: accuracy of current imaging modalities.

Authors:  George A Alexiou; Spyridon Tsiouris; Athanasios P Kyritsis; Spyridon Voulgaris; Maria I Argyropoulou; Andreas D Fotopoulos
Journal:  J Neurooncol       Date:  2009-04-21       Impact factor: 4.130

Review 3.  Use of 99m-technetium-glucoheptonate as a tracer for brain tumor imaging: An overview of its strengths and pitfalls.

Authors:  Amburanjan Santra; Rakesh Kumar; Punit Sharma
Journal:  Indian J Nucl Med       Date:  2015 Jan-Mar

4.  Tc-99m Glucoheptonate Single Photon Emission Computed Tomography-Computed Tomography for Detection of Recurrent Glioma: A Prospective Comparison with N-13 Ammonia Positron Emission Tomography-Computed Tomography.

Authors:  Bangkim Chandra Khangembam; Abhinav Singhal; Rajeev Kumar; Chandrasekhar Bal
Journal:  Indian J Nucl Med       Date:  2019 Apr-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.