This paper describes a new type of non-contact electromagnetic transducer (EMAT) that can be used to generate both Lamb and Rayleigh waves on metal samples. The generated waves are wideband and low frequency with a dominant frequency content centred at approximately 200 kHz extending to around 500 kHz. The transducers have been used on both aluminium and steel, but operate more efficiently on aluminium due to its lower electrical resistance and density when compared to steel.Entities:
Year: 2004 PMID: 15234175 DOI: 10.1016/j.ultras.2004.02.019
Source DB: PubMed Journal: Ultrasonics ISSN: 0041-624X Impact factor: 2.890