Wavefront-customized intraocular lenses.

Griffith E Altmann1.   

Abstract

PURPOSE OF REVIEW: Recent advances in ocular wavefront measurement and in intraocular lens materials and manufacturing methods have brought cataract surgery to the brink of a period in which customized correction of higher-order aberrations with intraocular lenses may become standard practice. RECENT
FINDINGS: Retinal image quality in pseudophakic eyes is limited by the wavefront aberrations of the cornea and the intraocular lens. The Tecnis Z9000 is the first commercially available intraocular lens designed to account for the wavefront aberrations of the cornea, specifically spherical aberration. Clinical findings with the Tecnis Z9000 intraocular lens show improved contrast sensitivity at low and mid spatial frequencies. However, if the lens decenters or tilts modestly, higher-order aberrations are created, and the lens may underperform relative to standard intraocular lenses. At present, one firm is developing an intraocular lens that may be modified in vivo with near ultraviolet energy. Such a technology offers tremendous potential for a fully customized intraocular lens.
SUMMARY: Wavefront-customized intraocular lenses offer the promise of near perfect retinal image quality, such that only diffraction, chromatic aberration, retinal sampling and neural factors will limit vision in pseudophakic eyes.

Entities:  

Mesh:

Year:  2004        PMID: 15232477     DOI: 10.1097/00055735-200408000-00013

Source DB:  PubMed          Journal:  Curr Opin Ophthalmol        ISSN: 1040-8738            Impact factor:   3.761


  6 in total

1.  [Accuracy of lens power calculation and centration of an aspheric intraocular lens].

Authors:  K A Becker; M P Holzer; A J Reuland; G U Auffarth
Journal:  Ophthalmologe       Date:  2006-10       Impact factor: 1.059

2.  Comparison of wavefront aberrations in the object and image spaces using wide-field individual eye models.

Authors:  Yongji Liu; Xiaolan Li; Lin Zhang; Xianglong Yi; Yuwei Xing; Kunqi Li; Yan Wang
Journal:  Biomed Opt Express       Date:  2022-08-25       Impact factor: 3.562

3.  Correlation between contrast sensitivity and higher-order aberration based on pupil diameter after cataract surgery.

Authors:  Takefumi Yamaguchi; Kazuno Negishi; Kazuhiko Ohnuma; Kazuo Tsubota
Journal:  Clin Ophthalmol       Date:  2011-12-07

4.  Aspheric versus Spherical Posterior Chamber Intraocular Lenses.

Authors:  Mohammad-Reza Jafarinasab; Sepehr Feizi; Ahmad-Reza Baghi; Hossein Ziaie; Mehdi Yaseri
Journal:  J Ophthalmic Vis Res       Date:  2010-10

5.  Influence on ocular surface after cataract surgery and effect of topical diquafosol on postoperative dry eye: a multicenter prospective randomized study.

Authors:  Kensaku Miyake; Norihiko Yokoi
Journal:  Clin Ophthalmol       Date:  2017-03-17

Review 6.  Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations.

Authors:  Zahra Ashena; Sundas Maqsood; Syed Naqib Ahmed; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2020-09-14