Literature DB >> 15227370

Bleeding aortic cannulation site: technique for repair.

A T Pezzella1.   

Abstract

A simple technique of controlling a bleeding aortic cannulation site employing autogenous tissue is described in which 3-0 Prolene suture is placed through the lateral pericardial tissue on both sides of the aortotomy closure in a horizontal mattress fashion. This technique is advantageous because of the availability of autogenous tissue, the ease in which the technique can be employed, the better conformance of the tissue to the suture line, and the elimination of the risk of infection from a foreign body.

Entities:  

Year:  1986        PMID: 15227370      PMCID: PMC324636     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  4 in total

1.  Safe cannulation of the ascending aorta.

Authors:  J E Liddicoat; S M Bekassy; J M Duncan; M E DeBakey
Journal:  Ann Thorac Surg       Date:  1976-01       Impact factor: 4.330

2.  Cannulation of the ascending aorta for cardiopulmonary bypass. Experience with 9,000 cases.

Authors:  P C Taylor; L K Groves; F D Loop; D Effler
Journal:  J Thorac Cardiovasc Surg       Date:  1976-02       Impact factor: 5.209

3.  Cannulation of the ascending aorta.

Authors:  P O Daily; T J Fogarty; N E Shumway
Journal:  Ann Thorac Surg       Date:  1971-07       Impact factor: 4.330

4.  Simplified approach to the management of bleeding operative sites on the ascending aorta.

Authors:  E B Dietrich; R Koopot; I Bahadir
Journal:  J Thorac Cardiovasc Surg       Date:  1982-08       Impact factor: 5.209

  4 in total