Literature DB >> 15227334

Results of heart valve replacement with the SORIN prosthesis.

T Colombo1, F Donatelli, E Quaini, E Vitali, A Pellegrini.   

Abstract

From March 1977 to December 1981, 872 patients at our institution underwent valve replacement with a pyrolytic carbon tilting disc prosthesis manufactured in Italy by SORIN-Biomedica. To verify the performance characteristics of this prosthesis, we analyzed the intermediate-term results obtained over a cumulative total of 3,041 patient-years (pt-yr) of follow-up. Three hundred sixty-nine patients underwent mitral valve replacement (MVR), 309 had aortic valve replacement (AVR), and 194 had both mitral and aortic (double) valve replacement (DVR). Expressed in actuarial terms (% [+/- standard error of the mean] free of adverse events at 5 years) and in linearized terms (% pt-yr), respectively, valve-related complications occurred at the following rates: Thromboembolism, 89.9 +/- 1.9% and 2.1 +/- 0.4% pt-yr (MVR); 92.1 +/- 1.9% and 1.7 +/- 0.4% (AVR); 90.5 +/- 5.0% and 2.2 +/- 0.6% (DVR). Anticoagulant-related hemorrhage, 95.2 +/- 1.5% and 1.4 +/- 0.3% (MVR); 95.9 +/- 1.5% and 1.3 +/- 0.3% (AVR); 96.0 +/- 2.0% and 0.9 +/- 0.4% (DVR). Prosthetic valve endocarditis, 99.0 +/- 0.6% and 0.2 +/- 0.1% (MVR); 97.4 +/- 1.0% and 0.6 +/- 0.2% (AVR); 94.5 +/- 1.7% and 1.4 +/- 0.4% (DVR). Reoperation, 92.6 +/- 1.5% and 1.7 +/- 0.3% (MVR); 89.4 +/- 1.9% and 2.4 +/- 0.4% (AVR); 82.3 +/- 2.9% and 4.8 +/- 0.8% (DVR). The total valve-related morbidity and mortality was 79.6 +/- 2.6% and 4.9 +/- 0.6% (MVR); 79.7 +/- 2.6% and 5.1 +/- 0.6% (AVR); 70.5 +/- 4.0% and 7.7 +/- 1.1% (DVR). The 5-year actuarial survival rate without hospital mortality was 86.8 +/- 2.0% (MVR), 91.0 +/- 1.7% (AVR), and 78.8 +/- 3.7% (DVR). The intermediate-term survival and complication rates showed the performance of the SORIN prosthesis to be quite satisfactory.

Entities:  

Year:  1987        PMID: 15227334      PMCID: PMC324697     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  20 in total

1.  A hydrodynamic evaluation of the new tilting disc valve (Björk-Shiley) for mitral valve replacement.

Authors:  V O Björk; C Olin
Journal:  Scand J Thorac Cardiovasc Surg       Date:  1970

2.  A hydrodynamic comparison between the new tilting disc aortic valve prosthesis (Björk-Shiley) and the corresponding prosthesis of Starr-Edwards, Kay-Shiley, Smeloff-Cutter and Wada-Cutter in the pulse duplicator.

Authors:  V O Björk; C Olin
Journal:  Scand J Thorac Cardiovasc Surg       Date:  1970

3.  The risk of reoperation in acquired valvular heart disease.

Authors:  G Rodewald; J Guntau; C Bantea; P Kalmar; H J Krebber; W Rödiger; V Tilsner
Journal:  Thorac Cardiovasc Surg       Date:  1980-04       Impact factor: 1.827

4.  Strut fracture of the Björk-Shiley aortic valve.

Authors:  P Jaumin; R Ponlot; J C Schoevaerdts; L Brasseur; C H Chalant
Journal:  J Thorac Cardiovasc Surg       Date:  1984-11       Impact factor: 5.209

5.  Ten years' experience with the Björk-Shiley tilting disc valve.

Authors:  V O Björk; A Henze
Journal:  J Thorac Cardiovasc Surg       Date:  1979-09       Impact factor: 5.209

6.  Replacement of prosthetic heart valves. A fifteen-year experience.

Authors:  J G Sandza; R E Clark; T B Ferguson; J P Connors; C S Weldon
Journal:  J Thorac Cardiovasc Surg       Date:  1977-12       Impact factor: 5.209

7.  Long-term follow-up of isolated replacement of the aortic or mitral valve with the Starr-Edwards prosthesis.

Authors:  D A Barnhorst; H A Oxman; D C Connolly; J R Pluth; G K Danielson; R B Wallace; D C McGoon
Journal:  Am J Cardiol       Date:  1975-02       Impact factor: 2.778

8.  [Emergencies in valvular surgery].

Authors:  P Colombi; F Donatelli; G Pomé; E Quaini; C Rossi; E Vitali
Journal:  G Ital Cardiol       Date:  1983-12

9.  Nine years' experience with the Björk-Shiley prosthetic valve: early and late results of 932 valve replacements.

Authors:  W Daenen; A Nevelsteen; P van Cauwelaert; E de Maesschalk; J Willems; G Stalpaert
Journal:  Ann Thorac Surg       Date:  1983-06       Impact factor: 4.330

10.  Long term results of isolated mitral and aortic valve replacement. A statistical evaluation.

Authors:  A Pellegrini; B Peronace; E Marcazzan; C Rossi
Journal:  J Cardiovasc Surg (Torino)       Date:  1983 Sep-Oct       Impact factor: 1.888

View more
  1 in total

1.  Mitral valve replacement with the SORIN valve. Long-term follow-up of 1,161 patients.

Authors:  A Pellegrini; T Colombo; E Quaini; C Russo; E Vitali; F Donatelli
Journal:  Tex Heart Inst J       Date:  1991
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.