Literature DB >> 15227267

Tetralogy of fallot associated with a double aortic arch: palliation with a prosthetic tube graft.

R Tiraboschi1, E Manasse, L Parenzan.   

Abstract

Tetralogy of Fallot associated with a double aortic arch is an extremely rare congenital anomaly. Among the 785 patients who underwent definitive repair of tetralogy of Fallot between 1969 and 1985 at our center, only 1-a 19-month-old girl-had a double aortic arch. This report describes her case history, which included successful palliative repair with a polytetrafluoroethylene (PTFE) tube graft.

Entities:  

Year:  1988        PMID: 15227267      PMCID: PMC324807     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  7 in total

1.  Seminar on aortic vascular rings and other anomalies of the aortic arch.

Authors:  S BLUMENTHAL; M M RAVITCH
Journal:  Pediatrics       Date:  1957-11       Impact factor: 7.124

2.  Double aortic arch; report of two cases and review of the literature.

Authors:  H E GRISWOLD; M D YOUNG
Journal:  Pediatrics       Date:  1949-12       Impact factor: 7.124

3.  Double aortic arch associated with tetralogy of Fallot in infants; report of two cases.

Authors:  J P Binet; J Carpentier; M Pottemain; J Langlois
Journal:  J Thorac Cardiovasc Surg       Date:  1966-01       Impact factor: 5.209

4.  Systemic-pulmonary artery shunt using PTFE prosthesis (Gore-Tex). Early results and long-term follow-up on 105 consecutive cases.

Authors:  G Di Benedetto; R Tiraboschi; V Vanini; P Annecchino; L Aiazzi; C Caprioli; L Parenzan
Journal:  Thorac Cardiovasc Surg       Date:  1981-06       Impact factor: 1.827

5.  Late effects on the left upper limb of subclavian flap aortoplasty.

Authors:  P J Todd; P H Dangerfield; D I Hamilton; J L Wilkinson
Journal:  J Thorac Cardiovasc Surg       Date:  1983-05       Impact factor: 5.209

6.  Upper extremity gangrene: a complication of subclavian artery division.

Authors:  D Geiss; W G Williams; W K Lindsay; R D Rowe
Journal:  Ann Thorac Surg       Date:  1980-11       Impact factor: 4.330

7.  Modified Blalock-Taussig shunt. Use of subclavian artery orifice as flow regulator in prosthetic systemic-pulmonary artery shunts.

Authors:  M R de Leval; R McKay; M Jones; J Stark; F J Macartney
Journal:  J Thorac Cardiovasc Surg       Date:  1981-01       Impact factor: 5.209

  7 in total
  1 in total

1.  Dysphagia in an Adult Tetralogy of Fallot with Double aortic arch.

Authors:  B Pankaj; T Munesh; A Bhan
Journal:  Images Paediatr Cardiol       Date:  2013 Jul-Sep
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.