Literature DB >> 15227151

Determination of cardiac output and ejection fraction with the dual cardiac probe.

C G Cardenas1, E G DePuey, W L Thompson, E Garcia, J A Burdine.   

Abstract

Cardiac output and left ventricular ejection fraction were determined noninvasively at the bedside in 26 patients by using a dual scintillation probe. The probe is a nonimaging detector that records a high frequency time-activity curve of the passage of an intravenously injected radioactive bolus through the heart. Results were correlated with ejection fraction measured by biplane cineangiography (r = 0.80) and cardiac output determined by green dye dilution (R = 0.86). It is concluded that the dual probe provides an accurate noninvasive means of measuring these parameters, and that it may be particularly applicable to serial measurements in patients in the intensive care unit.

Entities:  

Year:  1983        PMID: 15227151      PMCID: PMC341600     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  9 in total

1.  Evaluation of portable radionuclide method for measurement of left ventricular ejection fraction and cardiac output.

Authors:  T Berndt; E L Alderman; R Wasnich; S C Hsieh; D Van Dyke; D C Harrison
Journal:  J Nucl Med       Date:  1975-04       Impact factor: 10.057

2.  Cine coronary arteriography.

Authors:  F M SONES; E K SHIREY
Journal:  Mod Concepts Cardiovasc Dis       Date:  1962-07

3.  A new dual-probe system for the rapid bedside assessment of left ventricular function.

Authors:  M W Groch; S Gottlieb; S M Mallon; A Miale
Journal:  J Nucl Med       Date:  1976-10       Impact factor: 10.057

4.  A correlative study of the measurement of human cardiac output as determined by thermodilution and radiocardiography.

Authors:  P Minssart; J F Chatal; J Y Grolleau; R Guihard; J Agnely; P De Vernejoul
Journal:  Eur J Nucl Med       Date:  1978-07-01

5.  Clinical standardization of the new dual cardiac probe.

Authors:  E G DePuey; V S Mathur; E G Garcia; J A Burdine
Journal:  Radiology       Date:  1979-07       Impact factor: 11.105

6.  Measurement of left ventricular ejection fraction.

Authors:  R H Secker-Walker; L Resnick; H Kunz; J A Parker; R L Hill; E J Potchen
Journal:  J Nucl Med       Date:  1973-11       Impact factor: 10.057

7.  Comparison of ultrasound and cineangiographic measurements of left ventricular performance in patients with and without wall motion abnormalities.

Authors:  P Ludbrook; J S Karliner; K Peterson; G Leopold; R A O'Rourke
Journal:  Br Heart J       Date:  1973-10

8.  The echocardiogram in right ventricular overload.

Authors:  W D McCann; N B Harbold; E R Giuliani
Journal:  JAMA       Date:  1972-09-11       Impact factor: 56.272

9.  Tc-99m human serum albumin: a suitable agent for plasma volume measurements in man.

Authors:  S S Yang; E L Nickoloff; P A McIntyre; W C Maddrey; H H Mikesell; U Scheffel; W Kasecamp; N P MacAllister
Journal:  J Nucl Med       Date:  1978-07       Impact factor: 10.057

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.