Literature DB >> 15227040

Intermediate term evaluation of Starr-Edwards ball valves in the mitral position.

M Cotrufo1, A Renzulli, V Esposito, C Vosa, G Nappi, L DeLuca, D Casale, R Bellitti, M Festa.   

Abstract

The Model 6120 ball valve prosthesis introduced in 1965 is still strongly supported as a mitral valve substitute in many centers around the world. A current reassessment of the performance of this prosthesis is therefore pertinent to current medical practice. In this institution since 1974, 227 Starr-Edwards caged ball valves have been implanted in the mitral position during isolated valve replacement. Two models of caged ball valves were used concurrently: the silastic ball valve in 108 patients (48%) and the composite strut "tract" valve in 119 (52%). Hospital mortality was 7%, and 8-year survival (standard error) was 74 (6%), with 100% follow-up, documenting 752 total patient-years. No late deaths were known to be valve related, and there were no cases of prosthetic thrombosis. The actuarial estimate of patients free from thromboembolism at 8 years was 89 (4%) with a linearized rate of 1.3% per year. At the most recent follow-up, 95% of the patients were in the New York Heart Association (NYHA) Classes I or II. These good results were partly due to an awareness at operation of ventricular outflow tract size requirements and to strict control of postoperative anticoagulation. We conclude that the Starr-Edwards ball valve is the mitral valve of choice in the young patient who is able to take anticoagulation drugs and has a left ventricular outflow tract of satisfactory size.

Entities:  

Year:  1985        PMID: 15227040      PMCID: PMC341791     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  5 in total

1.  Mitral replacement: clinical experience with a ball-valve prosthesis.

Authors:  A STARR; M L EDWARDS
Journal:  Ann Surg       Date:  1961-10       Impact factor: 12.969

2.  Selection of a prosthetic heart valve.

Authors:  A Starr; G L Grunkemeier
Journal:  JAMA       Date:  1984-04-06       Impact factor: 56.272

Review 3.  Current status of cardiac valve replacement: selection of a prosthesis and indications for operation.

Authors:  L I Bonchek
Journal:  Am Heart J       Date:  1981-01       Impact factor: 4.749

4.  Ten to fifteen year reassessment of the performance characteristics of the Starr-Edwards Model 6120 mitral valve prosthesis.

Authors:  D C Miller; P E Oyer; E B Stinson; B A Reitz; S W Jamieson; W A Baumgartner; R S Mitchell; N E Shumway
Journal:  J Thorac Cardiovasc Surg       Date:  1983-01       Impact factor: 5.209

5.  Review of 387 isolated mitral valve replacements by the Model 6120 Starr-Edwards prosthesis.

Authors:  A Sala; J C Schoevaerdts; P Jaumin; R Ponlot; C H Chalant
Journal:  J Thorac Cardiovasc Surg       Date:  1982-11       Impact factor: 5.209

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.