Anatomical factors influencing fixation of endocardial pacing leads in the right ventricle.

S Victor1, P Ravindran.   

Abstract

The anatomical factors influencing fixation of endocardial pacing leads were studied in 50 hearts. Many variations were found in the anterior, posterior and septal papillary muscles, interpapillary connections, and the moderator band. Those variations conducive to lead fixation are illustrated. Vertical bands of muscle that could influence lead fixation were seen inside the right ventricle. Variations in the conus papillary muscle and right ventricular outflow tract that facilitate lead fixation are also illustrated. In a few hearts, attention is drawn to slender support of the anterior cusp of the tricuspid valve.

Entities:  

Year:  1985        PMID: 15227038      PMCID: PMC341786     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  8 in total

1.  Complications with permanent endocardial electrode systems.

Authors:  O J Ohm; L Segadal; D W Skagen
Journal:  Acta Med Scand Suppl       Date:  1976

2.  Pericardial tamponade due to perforation with a permanent endocardial pacing catheter.

Authors:  M M Bassan; G Merin
Journal:  J Thorac Cardiovasc Surg       Date:  1977-07       Impact factor: 5.209

3.  Perforation of the tricuspid valve by a transvenous pacemaker.

Authors:  L Gould; C V Reddy; U Yacob; M Teich; A DeMartino; D DePalma; R F Gomprecht
Journal:  JAMA       Date:  1974-10-07       Impact factor: 56.272

4.  Tricuspid valve perforation by endocardial pacing electrode.

Authors:  S R Petterson; J B Singh; G Reeves; S L Kocot
Journal:  Chest       Date:  1973-01       Impact factor: 9.410

5.  Unusual complications of endocardial pacing.

Authors:  M E Lee; A Chaux
Journal:  J Thorac Cardiovasc Surg       Date:  1980-12       Impact factor: 5.209

6.  The incidence of venous thrombosis following long-term transvenous pacing.

Authors:  W S Stoney; R B Addlestone; W C Alford; G R Burrus; R A Frist; C S Thomas
Journal:  Ann Thorac Surg       Date:  1976-08       Impact factor: 4.330

7.  Follow-up experience with permanent endocardial tined pacemaker electrodes.

Authors:  D R Holmes; B J Gersh; J D Maloney; J Merideth
Journal:  J Thorac Cardiovasc Surg       Date:  1980-04       Impact factor: 5.209

8.  Helifix, an electrode suitable for transvenous atrial and ventricular implantation.

Authors:  L Bergdahl
Journal:  J Thorac Cardiovasc Surg       Date:  1980-11       Impact factor: 5.209

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.