Two years' experience with the duromedics bileaflet heart valve prosthesis.

A Moritz1, W Klepetko, F Grabenwoger, W Schreiner, M Klicpera, G Kronik, E Wolner.   

Abstract

The new Duromedics Bileaflet Cardiac Valve prosthesis has a special moving hinge mechanism for its two leaflets to wash the critical articulation area and thus reduce thrombus formation. Between October 1983 and June 1985, we implanted 278 of these prostheses in 254 patients. We did 114 aortic valve replacements, 109 mitral valve replacements, 34 double valve replacements, and two tricuspid valve replacements. Nearly 20% of the patients had had previous cardiac procedures. The hospital mortality was 5.9%. Follow-up was started with 214 surviving Austrian patients, and up to the present time, we have a follow-up period of 1704 patient months. Five patients died late after the operation (3.5 per 100 patient years). We observed 10 valve-related complications in nine patients (7 per 100 patient years). There were three cases of prosthetic endocarditis (2.1 per 100 patient years), two paravalvular leaks, and four bleeding episodes (2.8 per 100 patient years). The mechanical hemolysis was minimal, and the postoperative hemoglobin value averaged 15 g%. The LDH increased from 230 IU to 307 in the aortic valve replacements, 406 in the mitral valve replacements, and 435 in the double valve replacements. Intraoperative pressure gradients and postoperative Doppler echocardiography showed good hemodynamic performance. We conclude that good clinical results and a low complication rate can be achieved with the Duromedics Valve.

Entities:  

Year:  1985        PMID: 15226987      PMCID: PMC341882     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  8 in total

1.  Platelet survival in patients with homograft and prosthetic heart valves. Correlation with incidence of thromboembolism.

Authors:  S M Manohitharajah; A N Rahman; R J Donnelly; P B Deverall; D A Watson
Journal:  Thorax       Date:  1974-11       Impact factor: 9.139

2.  Study of platelet diameter distribution in patients with valvular heart disease and with prosthetic heart valve replacement.

Authors:  M Dumoulin; M Tirmarche; M H Horellou; J Acar; M Samama
Journal:  Haemostasis       Date:  1981

3.  Ten years' experience with the Björk-Shiley tilting disc valve.

Authors:  V O Björk; A Henze
Journal:  J Thorac Cardiovasc Surg       Date:  1979-09       Impact factor: 5.209

4.  The ultimate prognosis after valve replacement: an assessment at twenty years.

Authors:  J F Teply; G L Grunkemeier; H D Sutherland; L E Lambert; V A Johnson; A Starr
Journal:  Ann Thorac Surg       Date:  1981-08       Impact factor: 4.330

5.  Intravascular hemolysis in the late course of aortic valve.

Authors:  J Dale; E Myhre
Journal:  Am Heart J       Date:  1978-07       Impact factor: 4.749

6.  Platelet alpha granule depletion: findings in patients with prosthetic heart valves and following cardiopulmonary bypass surgery.

Authors:  C W Pumphrey; J Dawes
Journal:  Thromb Res       Date:  1983-05-01       Impact factor: 3.944

7.  Performance characteristics of the Starr-Edwards Model 1260 aortic valve prosthesis beyond ten years.

Authors:  D C Miller; P E Oyer; R S Mitchell; E B Stinson; S W Jamieson; J C Baldwin; N E Shumway
Journal:  J Thorac Cardiovasc Surg       Date:  1984-08       Impact factor: 5.209

8.  Clinical and hemodynamic results with the St. Jude Medical cardiac valve prosthesis. A three-year experience.

Authors:  D M Nicoloff; R W Emery; K V Arom; W F Northrup; C R Jorgensen; Y Wang; W G Lindsay
Journal:  J Thorac Cardiovasc Surg       Date:  1981-11       Impact factor: 5.209

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.