Literature DB >> 15226952

Removal of iatrogenic foreign bodies within cardiac chambers with a new snare catheter.

A Lijoi1, L Barberis, G C Passerone, G Venere.   

Abstract

A technique for extracting an embolized venous catheter lodged in the pulmonary artery is described. A Deyhle-Seuberth catheter, which is generally used to excise gastrointestinal polyps, was used successfully to accomplish the extraction.

Entities:  

Year:  1982        PMID: 15226952      PMCID: PMC351605     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  19 in total

1.  Snaring of a Swan-Ganz catheter.

Authors:  P C Block
Journal:  J Thorac Cardiovasc Surg       Date:  1976-06       Impact factor: 5.209

2.  Removal of catheter fragments from pulmonary artery using a snare.

Authors:  E Schechter; A F Parisi
Journal:  Br Heart J       Date:  1972-07

3.  Migration of a severed transvenous pacing catheter and its successful removal.

Authors:  B W Ramo; R H Peter; Y Kong; J J Morris
Journal:  Am J Cardiol       Date:  1968-12       Impact factor: 2.778

4.  Polyethylene catheter embolism. Review of the literature and report of a case with associated fatal tricuspid and systemic candidiasis.

Authors:  K F Wellmann; A Reinhard; E P Salazar
Journal:  Circulation       Date:  1968-03       Impact factor: 29.690

5.  Percutaneous removal of flexible foreign body from the heart.

Authors:  F T Henley; J W Ballard
Journal:  Radiology       Date:  1969-01       Impact factor: 11.105

6.  Non-surgical extraction of a broken catheter sheath lodged in the right atrium, using a Dormia ureteral stone dislodger.

Authors:  P L Wahi; K K Talwar; R P Sapru
Journal:  Br Heart J       Date:  1980-09

7.  Complications of indwelling venous catheters, with particular reference to catheter embolus.

Authors:  R B Doering; E A Stemmer; J E Connolly
Journal:  Am J Surg       Date:  1967-08       Impact factor: 2.565

8.  Atraumatic, nonsurgical technic for removal of broken catheters from cardiac cavities.

Authors:  R A Massumi; A M Ross
Journal:  N Engl J Med       Date:  1967-07-27       Impact factor: 91.245

9.  Removal of an iatrogenic foreign body from the aorta by means of a ureteric stone catcher.

Authors:  B W Lassers; D Pickering
Journal:  Am Heart J       Date:  1967-03       Impact factor: 4.749

10.  Nonsurgical removal of foreign body from right heart. A new percutaneous approach.

Authors:  J F King; J C Manley; H J Zeft; J E Auer
Journal:  J Thorac Cardiovasc Surg       Date:  1976-05       Impact factor: 5.209

View more