Three-dimensional echocardiography-guided atrial septectomy: an experimental study.

Yoshihiro Suematsu1, Gerald R Marx, John K Triedman, Tomislav Mihaljevic, Bassem N Mora, Shinichi Takamoto, Pedro J del Nido.   

Abstract

OBJECTIVES: The surgical feasibility of beating-heart atrial septectomy under the guidance of two different types of real-time 3-dimensional echocardiography systems was examined.
METHODS: A modified real-time 3-dimensional echocardiography system with a x4 matrix transducer (Sonos 7500; Philips Medical Systems, Andover, Mass) or a mechanical 1-dimensional array transducer (SSD-5500; Aloka Co, Ltd, Tokyo, Japan) was used. Small porcine atrial septal defects (n = 8) were enlarged with a Kerrison bone punch in the tank model. In the animal studies, small atrial septal defects (n = 8) were enlarged with the same device through a transatrial port. In both experiments, the area of the atrial septal defect measured by real-time 3-dimensional echocardiography was compared with the area measured directly.
RESULTS: Real-time 3-dimensional echocardiography provided satisfactory images and sufficient anatomic detail for the atrial septectomy in both experimental settings. All the atrial septal defects were successfully enlarged; an increase of as much as 293% of the preoperative atrial septal defect area was achieved in the tank experiment, and an increase of as great as 449% of the preoperative area was achieved in the animal experiment. The size of the atrial shunt was increased significantly after the atrial septectomy relative to that before the surgery (P <.0001). The percentage enlargement of the atrial septal defect measured by real-time 3-dimensional echocardiography was strongly correlated with that measured directly (both r(2) = 0.997, P <.0001) Bland-Altman analysis showed close agreement between the results obtained by the two measurement methods in both models.
CONCLUSIONS: Real-time 3-dimensional echocardiography provides satisfactory images and sufficient anatomic detail for atrial septectomy. This experiment demonstrates the surgical feasibility of a beating-heart intracardiac procedure such as atrial septectomy under real-time 3-dimensional echocardiographic guidance.

Entities:  

Mesh:

Year:  2004        PMID: 15224021     DOI: 10.1016/j.jtcvs.2004.03.008

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  4 in total

Review 1.  3D echocardiographic visualization for intracardiac beating heart surgery and intervention.

Authors:  Ivan S Salgo
Journal:  Semin Thorac Cardiovasc Surg       Date:  2007

2.  The state of ultrasound technology in the diagnosis and treatment of liver diseases now and in the future.

Authors:  Yasuharu Imai
Journal:  J Med Ultrason (2001)       Date:  2018-04       Impact factor: 1.314

3.  A novel cardioport for beating-heart, image-guided intracardiac surgery.

Authors:  Nikolay V Vasilyev; Mitsuhiro Kawata; Christopher M DiBiasio; Keith V Durand; Jonathan Hopkins; Zachary J Traina; Alexander H Slocum; Pedro J del Nido
Journal:  J Thorac Cardiovasc Surg       Date:  2011-09-08       Impact factor: 5.209

4.  Three dimensional echocardiography in congenital heart defects.

Authors:  Girish S Shirali
Journal:  Ann Pediatr Cardiol       Date:  2008-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.