Abstract

Increased compliance of abdominal aortic aneurysms at maximum diameter over time might be related to rupture. Compliance could, therefore, be valuable in their management. However, such measurement requires a sophisticated system. An original arterial wall-motion measurement technique, based on tissue Doppler imaging (TDI) and providing segmental exploration, was applied to the study of aorta walls. We report its validation in healthy subjects. Technical feasibility was reliable. The time required for sequence acquisition and transfer was suitable for routine clinical use and the quality of the sequences provided precise identification of the aorta wall/lumen interface and accurate segmentation. The values characterising normal aortic compliance were similar to those previously published, and the initial results concerning reproducibility were appropriate for clinical studies. Further refinements may improve it. This study validates the TDI system for measurement of abdominal aortic compliance in healthy subjects. Study of application to aneurysm compliance is in progress.

Entities:  

Mesh:

Year:  2004        PMID: 15219955     DOI: 10.1016/j.ultrasmedbio.2004.03.007

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  4 in total

1.  Age related changes of human aortic distensibility: evaluation with ECG-gated CT.

Authors:  Marika Ganten; Ute Krautter; Waldemar Hosch; Jochen Hansmann; Hendrik von Tengg-Kobligk; Stefan Delorme; Hans-Ulrich Kauczor; Günter W Kauffmann; Michael Bock
Journal:  Eur Radiol       Date:  2006-05-24       Impact factor: 5.315

Review 2.  Biomechanics of the cardiovascular system: the aorta as an illustratory example.

Authors:  Ghassan S Kassab
Journal:  J R Soc Interface       Date:  2006-12-22       Impact factor: 4.118

3.  Detecting Regional Stiffness Changes in Aortic Aneurysmal Geometries Using Pressure-Normalized Strain.

Authors:  Doran S Mix; Ling Yang; Camille C Johnson; Nathan Couper; Ben Zarras; Isaac Arabadjis; Lauren E Trakimas; Michael C Stoner; Steven W Day; Michael S Richards
Journal:  Ultrasound Med Biol       Date:  2017-07-17       Impact factor: 2.998

4.  Quantification of aortic distensibility in abdominal aortic aneurysm using ECG-gated multi-detector computed tomography.

Authors:  Maria-Katharina Ganten; Ute Krautter; Hendrik von Tengg-Kobligk; Dittmar Böckler; Hardy Schumacher; Wolfram Stiller; Stefan Delorme; Hans-Ulrich Kauczor; Günter W Kauffmann; Michael Bock
Journal:  Eur Radiol       Date:  2008-01-12       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.