Literature DB >> 15219020

Phase-sensitive optical low-coherence reflectometry for the detection of analyte concentrations.

Kirill V Larin1, Taner Akkin, Rinat O Esenaliev, Massoud Motamedi, Thomas E Milner.   

Abstract

Optical techniques may potentially be used for noninvasive glucose sensing. We investigated the application of phase-sensitive optical low-coherence reflectometry (PS-OLCR) to the measurement of analyte concentrations. The dependence of the PS-OLCR signal on the concentration of various analytes, including aqueous solutions of glucose, calcium chloride, magnesium chloride, sodium chloride, potassium chloride, potassium bicarbonate, urea, bovine serum albumin, and bovine globulin, were determined in clear and turbid media. Obtained results demonstrated (1) a high degree of sensitivity and accuracy of the phase measurements of analyte concentrations with PS-OLCR; (2) a concentration-dependent change in the phase-shift for glucose that is significantly greater than that of other analytes sampled over the same physiological range; and (3) a high submillimolar sensitivity of PS-OLCR for the measurement of glucose concentration. Further exploration of the application of PS-OLCR to the noninvasive, sensitive, and specific monitoring of glucose concentration seems warranted.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15219020     DOI: 10.1364/ao.43.003408

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  4 in total

1.  Prediction capability of optical coherence tomography for blood glucose concentration monitoring.

Authors:  Roman V Kuranov; Veronika V Sapozhnikova; Donald S Prough; Inga Cicenaite; Rinat O Esenaliev
Journal:  J Diabetes Sci Technol       Date:  2007-07

2.  Continuous noninvasive monitoring of changes in human skin optical properties during oral intake of different sugars with optical coherence tomography.

Authors:  Yuqing Zhang; Guoyong Wu; Huajiang Wei; Zhouyi Guo; Hongqin Yang; Yonghong He; Shusen Xie; Ying Liu
Journal:  Biomed Opt Express       Date:  2014-02-28       Impact factor: 3.732

3.  Real-Time Interferometric Refractive Index Change Measurement for the Direct Detection of Enzymatic Reactions and the Determination of Enzyme Kinetics.

Authors:  Søren T Jepsen; Thomas M Jørgensen; Henrik S Sørensen; Søren R Kristensen
Journal:  Sensors (Basel)       Date:  2019-01-28       Impact factor: 3.576

4.  Biosensing using microring resonator interferograms.

Authors:  Shih-Hsiang Hsu; Yung-Chia Yang; Yu-Hou Su; Sheng-Min Wang; Shih-An Huang; Ching-Yu Lin
Journal:  Sensors (Basel)       Date:  2014-01-10       Impact factor: 3.576