Literature DB >> 15216230

Echocardiographic analysis of a malfunctioning Davila-Sierra mitral valve.

Terry B. Tri1, Gabriel Gregoratos.   

Abstract

Although the Davila-Sierra mitral valve prosthesis was removed from the market nearly a decade ago, a number of patients still have this valve in place. We recently studied the echocardiographic features of a malfunctioning Davila-Sierra mitral valve prosthesis. Abnormalities that suggested improper functioning of the prosthesis included a markedly delayed poppet opening and an early diastolic hump believed to represent motion of the mitral annulus. Previously described echocardiographic indications of dys-function were not observed in our patient. We report the first known echocardiographic evaluation of a Davila-Sierra prosthesis.

Entities:  

Year:  1981        PMID: 15216230      PMCID: PMC287904     

Source DB:  PubMed          Journal:  Cardiovasc Dis        ISSN: 0093-3546


  11 in total

1.  Echocardiographic study of malfunction of the Bjork-Shiley prosthetic heart valve in the mitral position.

Authors:  J A Bernal-Ramirez; J H Phillips
Journal:  Am J Cardiol       Date:  1977-09       Impact factor: 2.778

2.  Echocardiographic determination of mitral disc valve excursion.

Authors:  M L Johnson; J H Holmes; B C Paton
Journal:  Circulation       Date:  1973-06       Impact factor: 29.690

3.  Dynamics of the Starr-Edwards ball valve prosthesis: a cine-fluorographic and ultrasonic study in humans.

Authors:  J L Gimenez; W L Winters; J C Davila; J Connell; K S Klein
Journal:  Am J Med Sci       Date:  1965-12       Impact factor: 2.378

4.  Echocardiographic features of the normal and malfunctioning porcine xenograft valve.

Authors:  P A Chandraratna; S B San Pedro
Journal:  Am Heart J       Date:  1978-05       Impact factor: 4.749

5.  Analysis of dynamics of mitral Starr-Edwards valve prosthesis using reflected ultrasound.

Authors:  D C Siggers; S A Srivongse; D Deuchar
Journal:  Br Heart J       Date:  1971-05

6.  Malfunction of mitral ball valve prosthesis due to thrombus. Report of 2 cases with notes on early clinical diagnosis.

Authors:  J Pfeifer; N Godlschlager; T Sweatman; F Gerbode; A Selzer
Journal:  Am J Cardiol       Date:  1972-01       Impact factor: 2.778

7.  Diagnosis of Björk-Shiley aortic valve dysfunction by echocardiography.

Authors:  P A Chandraratna; J M Lopez; F J Hildner; P Samet; J Ben-Zvi
Journal:  Am Heart J       Date:  1976-03       Impact factor: 4.749

8.  Clinical application of ultrasound in the analysis of prosthetic ball value function.

Authors:  W L Winters; J Gimenez; L A Soloff
Journal:  Am J Cardiol       Date:  1967-01       Impact factor: 2.778

9.  Noninvasive diagnosis of complications of the mitral bioprosthesis.

Authors:  M S Horowitz; D J Goodman; E W Hancock; R L Popp
Journal:  J Thorac Cardiovasc Surg       Date:  1976-03       Impact factor: 5.209

10.  Echocardiogram of the porcine aortic bioprosthesis in the mitral position.

Authors:  W N Bloch; J M Felner; C Wickliffe; P N Symbas; R C Schlant
Journal:  Am J Cardiol       Date:  1976-09       Impact factor: 2.778

View more
  1 in total

1.  Reoperation for late thrombosis of Lillehei-Kaster mitral valve prosthesis.

Authors:  Rosalyn Sterling
Journal:  Cardiovasc Dis       Date:  1981-06