Literature DB >> 15216088

DISC VARIANCE OF THE HARKEN MITRAL PROSTHESIS: THE CONTRIBUTION OF ASSOCIATED AORTIC REGURGITATION.

Michael D. Yarnoz1, David Hueter, John R. McCormick, Harrison Black, Robert L. Berger.   

Abstract

Four cases of severe mitral regurgitation due to disc variance of the Harken disc prosthesis in the mitral position are described. The valve occluder actually escaped into the left atrium in two patients, and neither survived despite emergency valve replacement. In the other two, disc malfunction was identified by flouroscopy, the prosthesis was replaced, and both patients survived. All four patients had associated aortic regurgitation, which most likely contributed to erosion of the disc edges. It is suggested that patients with the Harken disc prosthesis undergo periodic evaluation to detect abnormal disc motion.

Entities:  

Year:  1977        PMID: 15216088      PMCID: PMC287682     

Source DB:  PubMed          Journal:  Cardiovasc Dis        ISSN: 0093-3546


  15 in total

1.  Mitral valve replacement with a turtleneck-disc prosthesis.

Authors:  S S Oparah; J F Keefe; T J Ryan; R L Berger
Journal:  J Thorac Cardiovasc Surg       Date:  1975-04       Impact factor: 5.209

2.  A continuous suture technique for mitral valve replacement.

Authors:  R L Berger; V K Saini
Journal:  Ann Thorac Surg       Date:  1973-11       Impact factor: 4.330

3.  Mitral disc variance (Harken prosthesis).

Authors:  S D Sharma; R M Easley; L I Zaroff; S Goldstein
Journal:  Am Heart J       Date:  1973-11       Impact factor: 4.749

4.  An improved mitral valve prosthesis.

Authors:  A C Beall; G C Morris; G P Noon; G A Guinn; G J Reul; E A Lefrak; S D Greenberg
Journal:  Ann Thorac Surg       Date:  1973-01       Impact factor: 4.330

5.  Sudden mechanical malfunction of Hammersmith mitral valve prostheses due to wear of polypropylene.

Authors:  T R Shaw; J Gunstensen; R W Turner
Journal:  J Thorac Cardiovasc Surg       Date:  1974-04       Impact factor: 5.209

6.  Pathologic anatomy of cardiac valve replacement: a study of 224 necropsy patients.

Authors:  W C Roberts; B H Bulkley; A G Morrow
Journal:  Prog Cardiovasc Dis       Date:  1973 May-Jun       Impact factor: 8.194

7.  Mitral disc-valve variance.

Authors:  R B Berroya; F B Escano
Journal:  Thorax       Date:  1972-01       Impact factor: 9.139

8.  A new mitral valve.

Authors:  D E Harken; J M Matloff; W Zuckerman; A Chaux
Journal:  J Thorac Cardiovasc Surg       Date:  1968-03       Impact factor: 5.209

9.  A complication of mitral-valve replacement with caged-lens prosthesis.

Authors:  J S Carey; R K Hughes
Journal:  Ann Thorac Surg       Date:  1968-07       Impact factor: 4.330

10.  Acute massive mitral regurgitation resulting from disc-valve malfunction.

Authors:  J S Vasko; R F Leighton
Journal:  Ann Thorac Surg       Date:  1968-12       Impact factor: 4.330

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.