Literature DB >> 15216087

LOW PROFILE BIOPROSTHESIS FOR CARDIAC VALVE REPLACEMENT: EARLY CLINICAL RESULTS.

Domingo Liotta1, Daniel Bracco, Helio Ferrari, Enrique Bertolozzi, Amadeo Pisanu, Osvaldo Donato.   

Abstract

Between May 1976 and April 1977, 100 patients underwent cardiac valve replacement with a unique low profile glutaraldehyde-treated porcine aortic xenograft. These patients were classified in four groups: Group I, 43 patients who underwent isolated mitral valve replacement (MVR); Group II, 27 patients who had isolated aortic valve replacement (AVR); Group III, 10 patients who had MVR and AVR; and Group IV, 20 patients who had MVR or AVR associated with other cardiac procedures. The operative mortality for Group I was 2.3% (1 of 43) and 15% (3 of 20) in Group IV. The total operative mortality was 4% (4 of 100) and the late mortality was 1.02% (1 of 96 survivors), who died apparently secondary to a cardiac arrhythmia. During a follow-up period extending for 16 months, thromboembolic complications occurred early in the postoperative period in 3% (3 of 100), one patient with neurological residual, and two patients with transient symptoms only. The embolic complications occurred only in Group I. Considering all patients in whom the mitral valves were replaced, the incidence of emboli was 4.9% (3 of 61). The 96 patients did not receive anticoagulant therapy. Reoperation was necessary in one patient because of periprosthetic leak. The incidence of endocarditis was 1.02% (1 of 96 survivors). We recommend anticoagulant therapy for eight to twelve weeks postoperatively in MVR patients after bioprosthetic insertion.

Entities:  

Year:  1977        PMID: 15216087      PMCID: PMC287681     

Source DB:  PubMed          Journal:  Cardiovasc Dis        ISSN: 0093-3546


  5 in total

1.  Mitral replacement: clinical experience with a ball-valve prosthesis.

Authors:  A STARR; M L EDWARDS
Journal:  Ann Surg       Date:  1961-10       Impact factor: 12.969

2.  Partial and complete prostheses in aortic insufficiency.

Authors:  D E HARKEN; H S SOROFF; W J TAYLOR; A A LEFEMINE; S K GUPTA; S LUNZER
Journal:  J Thorac Cardiovasc Surg       Date:  1960-12       Impact factor: 5.209

3.  Clinical experience with a porcine aortic valve xenograft for mitral valve replacement.

Authors:  E B Stinson; R B Griepp; N E Shumway
Journal:  Ann Thorac Surg       Date:  1974-10       Impact factor: 4.330

4.  The flexible stent. A new concept in the fabrication of tissue heart valve prostheses.

Authors:  R L Reis; W D Hancock; J W Yarbrough; D L Glancy; A G Morrow
Journal:  J Thorac Cardiovasc Surg       Date:  1971-11       Impact factor: 5.209

5.  Biological factors affecting long-term results of valvular heterografts.

Authors:  A Carpentier; G Lemaigre; L Robert; S Carpentier; C Dubost
Journal:  J Thorac Cardiovasc Surg       Date:  1969-10       Impact factor: 5.209

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.