Literature DB >> 15215968

INTRACORPOREAL HEAT DISSIPATION FROM A RADIOISOTOPE-POWERED ARTIFICIAL HEART.

Fred N. Huffman1, Kenneth G. Hagen, Robert L. Whalen, John M. Fuqua, John C. Norman.   

Abstract

The feasibility of radioisotope-fueled circulatory support systems depends on the ability of the body to dissipate the reject heat from the power source driving the blood pump as well as to tolerate chronic intracorporeal radiation. Our studies have focused on the use of the circulating blood as a heat sink. Initial in vivo heat transfer studies utilized straight tube heat exchangers (electrically and radioisotope energized) to replace a segment of the descending aorta. More recent studies have used a left ventricular assist pump as a blood-cooled heat exchanger. This approach minimizes trauma, does not increase the area of prosthetic interface with the blood, and minimizes system volume. Heat rejected from the thermal engine (vapor or gas cycle) is transported from the nuclear power source in the abdomen to the pump in the thoracic cavity via hydraulic lines. Adjacent tissue is protected from the fuel capsule temperature (900 to 1200 degrees F) by vacuum foil insulation and polyurethane foam. The in vivo thermal management problems have been studied using a simulated thermal system (STS) which approximates the heat rejection and thermal transport mechanisms of the nuclear circulatory support systems under development by NHLI. Electric heaters simulate the reject heat from the thermal engines. These studies have been essential in establishing the location, suspension, surgical procedures, and postoperative care for implanting prototype nuclear heart assist systems in calves. The pump has a thermal impedance of 0.12 degrees C/watt. Analysis of the STS data in terms of an electrical analog model implies a heat transfer coefficient of 4.7 x 10(-3) watt/cm(2) degrees C in the abdomen compared to a value of 14.9 x 10(-3) watt/cm(2) degrees C from the heat exchanger plenum into the diaphragm.

Entities:  

Year:  1974        PMID: 15215968      PMCID: PMC287500     

Source DB:  PubMed          Journal:  Cardiovasc Dis        ISSN: 0093-3546


  2 in total

1.  Development of an experimental model for functional cardiac replacement.

Authors:  W F Bernhard; M A Bankole; C G LaFarge; W Bornhorst; S Frieze; G W Curtis
Journal:  Surgery       Date:  1971-08       Impact factor: 3.982

2.  Physiologic observations during partial and total left heart bypass.

Authors:  W F Bernhard; C G LaFarge; M Husain; N Yamamura; T C Robinson
Journal:  J Thorac Cardiovasc Surg       Date:  1970-12       Impact factor: 5.209

  2 in total
  2 in total

1.  PREFABRICATION DESIGN CONSIDERATIONS FOR A LONG-TERM ELECTRICALLY-ACTUATED ABDOMINAL LEFT VENTRICULAR ASSIST DEVICE (E-TYPE ALVAD).

Authors:  James T. Sturm; Stephen R. Igo; Victor L. Poirier; John T. Keiser; C Wayne Hibbs; John M. Fuqua; Charles H. Edmonds; Daniel A. Holub; Michael G. McGee; Thomas M. Fuhrman; Alexander R. Joseph; John C. Norman
Journal:  Cardiovasc Dis       Date:  1978-12

2.  Intracorporeal Heat Distribution from Fully Implantable Energy Sources for Mechanical Circulatory Support: A Computational Proof-of-Concept Study.

Authors:  Jacopo Biasetti; Aliaksei Pustavoitau; Pier Giorgio Spazzini
Journal:  Front Bioeng Biotechnol       Date:  2017-10-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.