Literature DB >> 15210673

Concentrations of cardiac troponin T in neonates with and without respiratory distress.

S J Clark1, P Newland, C W Yoxall, N V Subhedar.   

Abstract

AIMS: To establish a practical postnatal reference range for cardiac troponin T in neonates and to investigate concentrations in neonates with respiratory distress.
METHODS: Prospective investigation in a tertiary neonatal unit, recruiting infants with and without respiratory distress (sick and healthy infants respectively). Concentrations of cardiac troponin T were compared between sick and healthy infants, accounting for confounding variables.
RESULTS: A total of 162 neonates (113 healthy and 49 sick infants) had samples taken. The median (interquartile range) cardiac troponin T concentration in the healthy infants was 0.025 (0.01-0.062) ng/ml, and the 95th centile was 0.153 ng/ml. There were no significant relations between cardiac troponin T and various variables. The median (interquartile range) cardiac troponin T concentration in the sick infants was 0.159 (0.075-0.308) ng/ml. This was significantly higher (p < 0.0001) than in the healthy infants. In a linear regression model, the use of inotropes and oxygen requirement were significant associations independent of other basic and clinical variables in explaining the variation in cardiac troponin T concentrations.
CONCLUSIONS: Cardiac troponin T is detectable in the blood of many healthy neonates, but no relation with important basic and clinical variables was found. Sick infants have significantly higher concentrations than healthy infants. The variations in cardiac troponin T concentration were significantly associated with oxygen requirement or the use of inotropic support in a regression model. Cardiac troponin T may be a useful marker of neonatal and cardiorespiratory morbidity.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15210673      PMCID: PMC1721706          DOI: 10.1136/adc.2002.025478

Source DB:  PubMed          Journal:  Arch Dis Child Fetal Neonatal Ed        ISSN: 1359-2998            Impact factor:   5.747


  23 in total

1.  Relation between troponin T concentration and mortality in patients presenting with an acute stroke: observational study.

Authors:  P James; C J Ellis; R M Whitlock; A R McNeil; J Henley; N E Anderson
Journal:  BMJ       Date:  2000-06-03

2.  Myocardial dysfunction and cerebral blood flow velocity following birth asphyxia.

Authors:  F Van Bel; F J Walther
Journal:  Acta Paediatr Scand       Date:  1990 Aug-Sep

3.  Mean arterial blood pressure and neonatal cerebral lesions.

Authors:  V M Miall-Allen; L S de Vries; A G Whitelaw
Journal:  Arch Dis Child       Date:  1987-10       Impact factor: 3.791

4.  Cardiac output in newborn infants with transient myocardial dysfunction.

Authors:  F J Walther; B Siassi; N A Ramadan; P Y Wu
Journal:  J Pediatr       Date:  1985-11       Impact factor: 4.406

5.  High serum cardiac troponin T concentrations in preterm infants with respiratory distress syndrome.

Authors:  D Trevisanuto; M Zaninotto; S Altinier; M Plebani; V Zanardo
Journal:  Acta Paediatr       Date:  2000-09       Impact factor: 2.299

6.  Cardiac troponin T in cord blood.

Authors:  S J Clark; P Newland; C W Yoxall; N V Subhedar
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2001-01       Impact factor: 5.747

7.  Prospective audit of incidence of prognostically important myocardial damage in patients discharged from emergency department.

Authors:  P O Collinson; S Premachandram; K Hashemi
Journal:  BMJ       Date:  2000-06-24

8.  Transient myocardial ischemia of the newborn infant demonstrated by thallium myocardial imaging.

Authors:  J P Finley; R B Howman-Giles; D L Gilday; K R Bloom; R D Rowe
Journal:  J Pediatr       Date:  1979-02       Impact factor: 4.406

9.  Echocardiographic assessment of cardiac function in shocked very low birthweight infants.

Authors:  A B Gill; A M Weindling
Journal:  Arch Dis Child       Date:  1993-01       Impact factor: 3.791

10.  Myocardial ischaemia in asphyxia neonatorum. Electrocardiographic, enzymatic and histological correlations.

Authors:  R A Primhak; R Jedeikin; G Ellis; S K Makela; J E Gillan; P R Swyer; R D Rowe
Journal:  Acta Paediatr Scand       Date:  1985-07
View more
  10 in total

1.  Sequential cardiac troponin T following delivery and its relationship with myocardial performance in neonates with respiratory distress syndrome.

Authors:  Simon J Clark; Paul Newland; C William Yoxall; Nimish V Subhedar
Journal:  Eur J Pediatr       Date:  2005-10-15       Impact factor: 3.183

2.  Cardiac Troponin-T as a Marker of Myocardial Dysfunction in Term Neonates with Perinatal Asphyxia.

Authors:  Susy Joseph; Sobha Kumar; Zulfikar Ahamed M; S Lakshmi
Journal:  Indian J Pediatr       Date:  2018-04-14       Impact factor: 1.967

3.  Cardiac troponin T and cardiac dysfunction in extremely low-birth-weight infants.

Authors:  M A Cruz; Y A Bremmer; B O Porter; S D Gullquist; K L Watterberg; H J Rozycki
Journal:  Pediatr Cardiol       Date:  2006 Jul-Aug       Impact factor: 1.655

4.  Frequency of elevations in markers of cardiomyocyte damage in otherwise healthy newborns.

Authors:  Steven E Lipshultz; Valeriano C Simbre; Sema Hart; Nader Rifai; Stuart R Lipsitz; Linda Reubens; Robert A Sinkin
Journal:  Am J Cardiol       Date:  2008-07-09       Impact factor: 2.778

5.  Cardiac troponin T and illness severity in the very-low-birth-weight infant.

Authors:  Danielle N Lopes; José M Moraes Ramos; Maria Elizabeth Lopes Moreira; Jofre A Cabral; Manoel de Carvalho; José Maria de Andrade Lopes
Journal:  Int J Pediatr       Date:  2012-02-22

6.  Myocardial injury in infants ventilated on the paediatric intensive care unit: a case control study.

Authors:  Simon J Clark; Michael Eisenhut; Dorothea Sidaras; Stephen W Hancock; Paul Newland; Kent Thorburn
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

7.  The Evaluation of Cardiac Troponin T in Newborns.

Authors:  Agata Tarkowska; Wanda Furmaga-Jabłońska
Journal:  Biomed Hub       Date:  2017-10-10

8.  Cardiac Troponin T in Healthy Full-Term Infants.

Authors:  Jonna Karlén; Mathias Karlsson; Håkan Eliasson; Anna-Karin Edstedt Bonamy; Cecilia Pegelow Halvorsen
Journal:  Pediatr Cardiol       Date:  2019-09-05       Impact factor: 1.655

9.  Troponin T and pro-B-type natriuretic Peptide in fetuses of type 1 diabetic mothers.

Authors:  Noirin E Russell; Mary F Higgins; Michael Amaruso; Michael Foley; F M McAuliffe
Journal:  Diabetes Care       Date:  2009-08-18       Impact factor: 17.152

10.  Cardiac troponin I levels and its relation to echocardiographic findings in infants of diabetic mothers.

Authors:  Afaf Korraa; Mohamed Hesham Ezzat; Mahmoud Bastawy; Hassan Aly; Abdel-Azeem El-Mazary; Lobna Abd El-Aziz
Journal:  Ital J Pediatr       Date:  2012-09-04       Impact factor: 2.638

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.