Literature DB >> 15209580

Mechanisms for enlarging lesion size during irrigated tip radiofrequency ablation: is there a virtual electrode effect?

Helen Høgh Petersen1, Javier Roman-Gonzalez, Susan B Johnson, Jesper Hastrup Svendsen, Stig HaunsØ, Douglas L Packer.   

Abstract

INTRODUCTION: Irrigated tip radiofrequency ablation of cardiac arrhythmias was developed to increase the size of the radiofrequency-induced lesion, since cooling of the electrode tip allows use of higher power settings. The purpose of this study was to determine if the increased lesion size during irrigated tip ablation is caused by the cooling effect solely or if increased electrical conductivity around the tip also contributes by increasing the "current-delivering size" of the tip: the so-called "virtual electrode effect." METHODS AND
RESULTS: In vitro strips of left ventricular porcine myocardium and in vivo canine left ventricles were ablated. In vitro closed loop tip and showerhead irrigated tip catheters were compared. In vitro and in vivo showerhead tip catheters irrigated with solutions having different ionic content were compared. We found no difference in lesion size for closed loop and showerhead-type catheters (998 +/- 345 vs. 811 +/- 313 mm(3) during power-controlled ablation and 227 +/- 76 vs 318 +/- 127 mm(3) during temperature-controlled ablation). For irrigation with liquids having increasing ionic strength we found a decrease in lesion volume in vitro (361 +/- 249 vs. 812 +/- 229 mm(3) (P < 0.001) for power-controlled and 156 +/- 78 vs. 318 +/- 127 mm(3) (P < 0.05) for temperature-controlled ablation and nonsignificant differences in vivo.
CONCLUSIONS: The mechanism for enlarging lesion size during radiofrequency irrigated-tip ablation is that higher power levels can be used. There is no virtual electrode effect caused by the highly conductive surroundings of the tip during irrigation. In vitro this effect is shown to be opposite: it decreases lesion size.

Entities:  

Mesh:

Year:  2004        PMID: 15209580     DOI: 10.1111/j.1540-8183.2004.09879.x

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  2 in total

1.  Catheter selection for ablation of the cavotricuspid isthmus for treatment of typical atrial flutter.

Authors:  Antoine Da Costa; Yann Jamon; Cécile Romeyer-Bouchard; Jérôme Thévenin; Marc Messier; Karl Isaaz
Journal:  J Interv Card Electrophysiol       Date:  2007-03-01       Impact factor: 1.900

2.  Radiofrequency ablation in snoring surgery: local tissue effects and safety measures.

Authors:  Jagdeep Singh Virk; Gaurav Kumar; Dhafir Al-Okati; Bhik Kotecha
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-06-27       Impact factor: 2.503

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.