Evaluation of gloss changes of two denture acrylic resin materials in four different beverages.

Filiz Keyf1, Ilker Etikan.   

Abstract

OBJECTIVES: The primary disadvantages of the materials which are used in construction of complete and removable partial dentures is that their esthetic, physical and mechanical properties change rapidly with time in the oral environment. For esthetics, color stability is one of the criteria that needs careful attention. Color may provide important information on the serviceability of these materials. Color change affects the gloss of these materials. The objective of the present study was to determine the gloss changes resulting from the testing process in four different beverages in one heat-polymerized denture base resin and one cold-polymerized denture base repair resin.
METHODS: Thirty-six samples were fabricated for each material. Each sample had a smooth polished and a rough unpolished surface. The gloss measurements were made with a glossmeter before testing. Four different beverages (tea, coffee, cola and cherry juice) were used for testing. Two angles of illumination (20 and 60 degrees) were used for the gloss measurements. The samples were immersed in water, tea, coffee, cola and cherry juice solutions. The gloss of the samples was measured again with the glossmeter at the end of the 45th day and 135th day of testing. The arithmetic mean and standard deviation of each of the samples were calculated and compared with each other statistically by using the Wilcoxon test (within times) (p < or = 0.05 significant), the Kruskal-Wallis analysis of variance (p < or = 0.05 significant) and the Mann-Whitney U-test with Bonforoni correction (when the difference between the samples was significant) (p < or = 0.05 significant).
RESULTS: The results of this study revealed that gloss changes occurred after testing in heat-polymerized denture base resin and cold-polymerized denture base repair resin. The significance of the gloss changes exhibited by each sample, kept for different lengths of time in the same solution, were compared using the Wilcoxon test. The results were statistically significant (p < or = 0.05). According to the Kruskal-Wallis analysis of variance, the difference between measurements for angles of illumination was statistically significant (p < or = 0.05). Also according to the Mann-Whitney U-test, the difference between two polished surfaces or two unpolished surfaces was statistically insignificant (p > 0.05), but the difference between smooth polished and rough unpolished surfaces was statistically significant (p < or = 0.05). SIGNIFICANCE: It was found that either the gloss of heat-polymerized denture base resin or the gloss of cold-polymerized denture base repair resin was affected by tested agents, and the four beverages demonstrated noticeable gloss changes. Cherry juice demonstrated the least change, while tea exhibited the greatest change.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15209229     DOI: 10.1016/S0109-5641(03)00099-X

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  8 in total

1.  Comparative evaluation of color change between two types of acrylic resin and flexible resin after thermo cycling. An in vitro study.

Authors:  Nadira A Hatim; Omar Zeno Al-Tahho
Journal:  J Indian Prosthodont Soc       Date:  2013-05-05

2.  Clinical performance of a light-cured denture base material compared to polymethylmethacrylate--a randomized clinical study.

Authors:  Hanna-Lena Gohlke-Wehrße; Katja Giese-Kraft; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2011-06-08       Impact factor: 3.573

3.  Effects of incorporating 45S5 bioactive glass into 30% hydrogen peroxide solution on whitening efficacy and enamel surface properties.

Authors:  Song-Yi Yang; A Ruem Han; Kwang-Mahn Kim; Jae-Sung Kwon
Journal:  Clin Oral Investig       Date:  2022-04-22       Impact factor: 3.606

4.  Colour Stability of Various Types of Acrylic Teeth Exposed to Coffee, Tea and Cola.

Authors:  Mousavi S; Narimani S; Hekmatfar S; Jafari K
Journal:  J Dent Biomater       Date:  2016-12

5.  Effects of thermocycling and various drinks on the color stability of heat-polymerized acrylic resin.

Authors:  Pinar Altinci; Pinar Durkaya
Journal:  J Istanb Univ Fac Dent       Date:  2016-10-01

6.  Evaluation of the Color Stability of Methyl Methacrylate and Nylon Base Polymer.

Authors:  Fahimeh Hamedi Rad; Tahereh Ghaffari; Raana Tamgaji
Journal:  J Dent (Shiraz)       Date:  2017-06

7.  Influence of Different Beverages on the Color Stability of Nanocomposite Denture Base Materials.

Authors:  Emad Azmy; Mohamed Reda Zaki Al-Kholy; Mohammed M Gad; Ahmad M Al-Thobity; Abdel-Naser M Emam; Mohamed Ahmed Helal
Journal:  Int J Dent       Date:  2021-11-11

8.  Surface roughness implant-retained mandibular bar and ball joint overdentures and adherence of microorganisms.

Authors:  Valenzuela Rocío; Daniel Valenzuela
Journal:  Eur J Dent       Date:  2018 Oct-Dec
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.