Literature DB >> 1520824

Re-evaluation of the biocompatibility of bioinert ceramics in vivo.

K Hayashi1, N Matsuguchi, K Uenoyama, Y Sugioka.   

Abstract

The affinity of bone for bioinert ceramics and stainless steel was compared using calcified bone specimens. We implanted cylinders of alumina ceramics (Al2O3), zirconia ceramics (ZrO2) and SUS-316 L stainless steel into the distal femoral epiphyses of dogs and then made observations from 4 to 96 wk post-operatively. Irregularities in the histological specimens suggested the presence of artefacts due to the insertion technique. We subsequently used screws inserted into holes tapped with a tap that had a diameter identical to the screws, and observed these implants from 4 to 96 wk after insertion. There was no detectable difference in the affinity index for all three materials from 4 to 96 wk after implantation. The affinity index was calculated as the ratio of the new bone directly adjoining the implant without any intervening fibrous membrane or bone marrow to the total length of the bone-implant interface x 100%.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1520824     DOI: 10.1016/0142-9612(92)90184-p

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  5 in total

1.  Effect of Surface Treatment with Carbon Dioxide (CO2) Laser on Bond Strength between Cement Resin and Zirconia.

Authors:  Shahin Kasraei; Mohammad Atefat; Maryam Beheshti; Nassimeh Safavi; Maryam Mojtahedi; Loghman Rezaei-Soufi
Journal:  J Lasers Med Sci       Date:  2014

Review 2.  Static and Dynamic Biomaterial Engineering for Cell Modulation.

Authors:  Hyung-Joon Park; Hyunsik Hong; Ramar Thangam; Min-Gyo Song; Ju-Eun Kim; Eun-Hae Jo; Yun-Jeong Jang; Won-Hyoung Choi; Min-Young Lee; Heemin Kang; Kyu-Back Lee
Journal:  Nanomaterials (Basel)       Date:  2022-04-17       Impact factor: 5.719

3.  Bond strength of resin cement to CO2 and Er:YAG laser-treated zirconia ceramic.

Authors:  Shahin Kasraei; Loghman Rezaei-Soufi; Bijan Heidari; Fariborz Vafaee
Journal:  Restor Dent Endod       Date:  2014-08-25

Review 4.  Progress in Niobium Oxide-Containing Coatings for Biomedical Applications: A Critical Review.

Authors:  Mir Saman Safavi; F C Walsh; Livia Visai; Jafar Khalil-Allafi
Journal:  ACS Omega       Date:  2022-03-11

5.  Fabrication of Parylene-Coated Microneedle Array Electrode for Wearable ECG Device.

Authors:  Afraiz Tariq Satti; Jinsoo Park; Jangwoong Park; Hansang Kim; Sungbo Cho
Journal:  Sensors (Basel)       Date:  2020-09-11       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.