Literature DB >> 15205549

HiResolution and conventional sound processing in the HiResolution bionic ear: using appropriate outcome measures to assess speech recognition ability.

Dawn Burton Koch1, Mary Joe Osberger, Phil Segel, Dorcas Kessler.   

Abstract

OBJECTIVE: This study compared speech perception benefits in adults implanted with the HiResolution (HiRes) Bionic Ear who used both conventional and HiRes sound processing. A battery of speech tests was used to determine which formats were most appropriate for documenting the wide range of benefit experienced by cochlear-implant users. STUDY
DESIGN: A repeated-measures design was used to assess postimplantation speech perception in adults who received the HiResolution Bionic Ear in a recent clinical trial. Patients were fit first with conventional strategies and assessed after 3 months of use. Patients were then switched to HiRes sound processing and assessed again after 3 months of use. To assess the immediate effect of HiRes sound processing on speech perception performance, consonant recognition testing was performed in a subset of patients after 3 days of HiRes use and compared with their 3-month performance with conventional processing.
SETTING: Subjects were implanted and evaluated at 19 cochlear implant programs in the USA and Canada affiliated primarily with tertiary medical centers. PATIENTS: Patients were 51 postlinguistically deafened adults. MAIN OUTCOME MEASURES: Speech perception was assessed using CNC monosyllabic words, CID sentences and HINT sentences in quiet and noise. Consonant recognition testing was also administered to a subset of patients (n = 30) using the Iowa Consonant Test presented in quiet and noise. All patients completed a strategy preference questionnaire after 6 months of device use.
RESULTS: Consonant identification in quiet and noise improved significantly after only 3 days of HiRes use. The mean improvement from conventional to HiRes processing was significant on all speech perception tests. The largest differences occurred for the HINT sentences in noise. Ninety-six percent of the patients preferred HiRes to conventional sound processing. Ceiling effects occurred for both sentence tests in quiet.
CONCLUSIONS: Although most patients improved after switching to HiRes sound processing, the greatest differences were seen in the 'poor' performers because 'good' performers often reached ceiling performance, especially on tests in quiet. Future evaluations of cochlear-implant benefit should make use of more difficult measures, especially for 'good' users. Nonetheless, a range of difficulty must remain in test materials to document benefit in the entire population of implant recipients. Copyright 2004 S. Karger AG, Basel

Entities:  

Mesh:

Year:  2004        PMID: 15205549     DOI: 10.1159/000078391

Source DB:  PubMed          Journal:  Audiol Neurootol        ISSN: 1420-3030            Impact factor:   1.854


  25 in total

1.  Talker-identification training using simulations of binaurally combined electric and acoustic hearing: generalization to speech and emotion recognition.

Authors:  Vidya Krull; Xin Luo; Karen Iler Kirk
Journal:  J Acoust Soc Am       Date:  2012-04       Impact factor: 1.840

Review 2.  Probing the electrode-neuron interface with focused cochlear implant stimulation.

Authors:  Julie Arenberg Bierer
Journal:  Trends Amplif       Date:  2010-06

3.  Partial tripolar cochlear implant stimulation: Spread of excitation and forward masking in the inferior colliculus.

Authors:  Julie Arenberg Bierer; Steven M Bierer; John C Middlebrooks
Journal:  Hear Res       Date:  2010-08-18       Impact factor: 3.208

Review 4.  Guidelines for Best Practice in the Audiological Management of Adults with Severe and Profound Hearing Loss.

Authors:  Laura Turton; Pamela Souza; Linda Thibodeau; Louise Hickson; René Gifford; Judith Bird; Maren Stropahl; Lorraine Gailey; Bernadette Fulton; Nerina Scarinci; Katie Ekberg; Barbra Timmer
Journal:  Semin Hear       Date:  2020-12-16

5.  Evaluation of TIMIT sentence list equivalency with adult cochlear implant recipients.

Authors:  Sarah E King; Jill B Firszt; Ruth M Reeder; Laura K Holden; Michael Strube
Journal:  J Am Acad Audiol       Date:  2012-05       Impact factor: 1.664

6.  Investigating the effects of stimulus duration and context on pitch perception by cochlear implant users.

Authors:  Joshua S Stohl; Chandra S Throckmorton; Leslie M Collins
Journal:  J Acoust Soc Am       Date:  2009-07       Impact factor: 1.840

7.  [Influence of "novel" speech processors on the speech perception performance of cochlear implant users].

Authors:  I Baljić
Journal:  HNO       Date:  2009-06       Impact factor: 1.284

8.  The effect of temporal gap identification on speech perception by users of cochlear implants.

Authors:  Elad Sagi; Adam R Kaiser; Ted A Meyer; Mario A Svirsky
Journal:  J Speech Lang Hear Res       Date:  2008-09-19       Impact factor: 2.297

9.  Psychophysical Tuning Curves as a Correlate of Electrode Position in Cochlear Implant Listeners.

Authors:  Lindsay DeVries; Julie G Arenberg
Journal:  J Assoc Res Otolaryngol       Date:  2018-06-04

Review 10.  Cochlear implants: system design, integration, and evaluation.

Authors:  Fan-Gang Zeng; Stephen Rebscher; William Harrison; Xiaoan Sun; Haihong Feng
Journal:  IEEE Rev Biomed Eng       Date:  2008-11-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.