Literature DB >> 15200981

Coronary flow characteristics after a Bentall procedure with or without sinuses of Valsalva.

Ruggero de Paulis1, Fabrizio Tomai, Fabio Bertoldo, Anna S Ghini, Raffaele Scaffa, Paolo Nardi, Luigi Chiariello.   

Abstract

OBJECTIVES: The sinuses of Valsalva are known to contribute to the normal function of the aortic valve. Little is known about their role in promoting coronary artery blood flow. The aim of this study was to compare coronary artery flow characteristics among patients undergoing a Bentall operation by means of a conventional cylindrical Dacron conduit or with a new conduit with pseudosinuses of Valsalva or in patients retaining their natural sinuses of Valsalva after aortic valve and supracoronary ascending aorta replacement.
METHODS: One year after a Bentall procedure with a standard cylindrical Dacron conduit (7 patients, group A) or with the new conduit (7 patients, group B), or after aortic valve and ascending aortic replacement (control group, 7 patients, group C) coronary flow velocity reserve and diastolic to systolic time integral ratio at baseline and after maximal hyperemia (with 40 microg of adenosine) were assessed by using a 0.014-in. Doppler guidewire positioned in the middle portion of the left anterior descending coronary artery. All patients were in NYHA class I, sinus rhythm and free of coronary disease.
RESULTS: Arterial blood pressures and heart rate were comparable among groups. Intracoronary Doppler measurements did not show any significant difference in coronary vascular reserve between the three groups (3.6+/-0.4 vs 3.1+/-0.7 vs 3.7+/-0.5, P = 0.2). A greater diastolic component at baseline was present in group B patients (5.5+/-1.9 vs 3.5+/-0.9 in group A and 3.7+/-0.9 in group C, P = 0.024). After maximal hyperemia the diastolic component increased slightly in group A patients (8%) while both in groups B and C significantly decreased (-15 and -20%, respectively) (P = 0.017).
CONCLUSIONS: The presence of pseudosinuses of Valsalva does not influence coronary flow reserve. After maximal coronary vasodilation the increase in the systolic component of coronary flow is more evident in the presence of sinuses or pseudosinuses of Valsalva, thus suggesting that coronary flow pattern may be affected by the presence of sinuses.

Entities:  

Mesh:

Year:  2004        PMID: 15200981     DOI: 10.1016/j.ejcts.2004.04.031

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  6 in total

1.  Simulation of the fluid dynamics in artificial aortic roots: comparison of two different types of prostheses.

Authors:  Christoph L Bara; Janko F Verhey
Journal:  J Artif Organs       Date:  2008-10-05       Impact factor: 1.731

2.  Coronary Flow Impacts Aortic Leaflet Mechanics and Aortic Sinus Hemodynamics.

Authors:  Brandon L Moore; Lakshmi Prasad Dasi
Journal:  Ann Biomed Eng       Date:  2015-01-31       Impact factor: 3.934

3.  In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology.

Authors:  Emaddin Kidher; Zhuo Cheng; Omar A Jarral; Declan P O'Regan; Xiao Yun Xu; Thanos Athanasiou
Journal:  J Cardiothorac Surg       Date:  2014-12-09       Impact factor: 1.637

4.  The evidence in a Bentall procedure with Valsalva graft: is this standard of care?

Authors:  Ziv Beckerman; Bradley G Leshnower; LaRonica McPherson; Jose N Binongo; Yi Lasanajak; Edward P Chen
Journal:  J Vis Surg       Date:  2018-05-10

Review 5.  Old Myths, New Concerns: the Long-Term Effects of Ascending Aorta Replacement with Dacron Grafts. Not All That Glitters Is Gold.

Authors:  Cristiano Spadaccio; Francesco Nappi; Nawwar Al-Attar; Fraser W Sutherland; Christophe Acar; Antonio Nenna; Marcella Trombetta; Massimo Chello; Alberto Rainer
Journal:  J Cardiovasc Transl Res       Date:  2016-05-31       Impact factor: 4.132

6.  Influence on fluid dynamics of coronary artery outlet angle variation in artificial aortic root prosthesis.

Authors:  Janko F Verhey; Christoph Bara
Journal:  Biomed Eng Online       Date:  2008-02-28       Impact factor: 2.819

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.